A randomized controlled clinical trial on press and block lithium disilicate partial crowns: a pilot study

IF 0.5 Q4 DENTISTRY, ORAL SURGERY & MEDICINE
E. F. Cagidiaco, A. Keeling, M. Ferrari
{"title":"A randomized controlled clinical trial on press and block lithium disilicate partial crowns: a pilot study","authors":"E. F. Cagidiaco, A. Keeling, M. Ferrari","doi":"10.23805/JO.2020.12.03.1","DOIUrl":null,"url":null,"abstract":"Aim Lithium disilicate is available in two formulations: press and block. The first requires an analog workflow, the latter a full digital workflow. The aim of this study was to evaluate clinical performance of two lithium disilicate systems by means of the novel Functional Index for Teeth (FIT) after one year of clinical service. \nMaterials and methods Partial adhesive crowns on posterior teeth were made on 60 patients, who were randomly divided into two groups: Group 1 Initial LiSi Press and Group 2 Initial LiSi Block (GC Co., Tokyo, Japan), which therefore followed full analog and digital workflows respectively. The restorations were followed-up for 1 year, and the FIT evaluation was performed at baseline and at last recall. The FIT includes 7 variables: Interproximal, Occlusion, Design, Mucosa, Bone, Biology and Margins, that are investigated using an intraoral radiograph and occlusal and buccal pictures and evaluated using a 0-1-2 score as follows. The presence or not of major, minor or no discrepancy (‘Interproximal’, ‘Occlusion’ and ‘Design’), presence or not of keratinized and attached gingiva (‘Mucosa’), presence of bone loss >1.5 mm, <1.5 mm or not detectable (‘Bone’), presence or not of Bleeding on Probing and or Plaque Index (‘Biology’), presence of detectable gap and marginal stain or not (‘Margins’). The Mann-Whitney ‘U’ test was used and a level of significance at p<0.05. Also, “success” of the crowns (restoration in place without any biological or technical complication) and “survival” (restoration still in place with biological or technical complication) were evaluated. \nResults All FIT parameters had high scores, between 1.85 and 2, and no statistically significant differences between the two groups were found (p>0.05). No statistically significant difference was found between baseline and recall scores. All FIT scores were compatible with the clinical success and not one restoration was replaced or repaired. The success rate at 1 year was 100%. \nConclusions The FIT can be a viable standardized evaluation of the quality of prosthodontic therapy. The two materials showed similar results at 1 year. Longer observation times are needed to confirm these preliminary results.","PeriodicalId":42724,"journal":{"name":"Journal of Osseointegration","volume":null,"pages":null},"PeriodicalIF":0.5000,"publicationDate":"2020-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Osseointegration","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23805/JO.2020.12.03.1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Aim Lithium disilicate is available in two formulations: press and block. The first requires an analog workflow, the latter a full digital workflow. The aim of this study was to evaluate clinical performance of two lithium disilicate systems by means of the novel Functional Index for Teeth (FIT) after one year of clinical service. Materials and methods Partial adhesive crowns on posterior teeth were made on 60 patients, who were randomly divided into two groups: Group 1 Initial LiSi Press and Group 2 Initial LiSi Block (GC Co., Tokyo, Japan), which therefore followed full analog and digital workflows respectively. The restorations were followed-up for 1 year, and the FIT evaluation was performed at baseline and at last recall. The FIT includes 7 variables: Interproximal, Occlusion, Design, Mucosa, Bone, Biology and Margins, that are investigated using an intraoral radiograph and occlusal and buccal pictures and evaluated using a 0-1-2 score as follows. The presence or not of major, minor or no discrepancy (‘Interproximal’, ‘Occlusion’ and ‘Design’), presence or not of keratinized and attached gingiva (‘Mucosa’), presence of bone loss >1.5 mm, <1.5 mm or not detectable (‘Bone’), presence or not of Bleeding on Probing and or Plaque Index (‘Biology’), presence of detectable gap and marginal stain or not (‘Margins’). The Mann-Whitney ‘U’ test was used and a level of significance at p<0.05. Also, “success” of the crowns (restoration in place without any biological or technical complication) and “survival” (restoration still in place with biological or technical complication) were evaluated. Results All FIT parameters had high scores, between 1.85 and 2, and no statistically significant differences between the two groups were found (p>0.05). No statistically significant difference was found between baseline and recall scores. All FIT scores were compatible with the clinical success and not one restoration was replaced or repaired. The success rate at 1 year was 100%. Conclusions The FIT can be a viable standardized evaluation of the quality of prosthodontic therapy. The two materials showed similar results at 1 year. Longer observation times are needed to confirm these preliminary results.
压块二硅酸锂部分冠的随机对照临床试验:一项初步研究
目的二硅酸锂有两种配方:压型和块型。前者需要模拟工作流,后者需要全数字工作流。本研究的目的是通过新型牙齿功能指数(FIT)在临床服务一年后评估两种二硅酸锂系统的临床性能。材料与方法对60例患者进行后牙部分粘接剂冠的制作,随机分为两组:第一组Initial LiSi Press和第二组Initial LiSi Block (GC Co., Tokyo, Japan),分别采用全模拟和全数字化的工作流程。修复体随访1年,并在基线和最后回忆时进行FIT评估。FIT包括7个变量:近端间、咬合、设计、黏膜、骨、生物学和边缘,使用口内x线片和咬合和颊片进行调查,并使用0-1-2评分如下。是否存在严重、轻微或无差异(“近端间”、“咬合”和“设计”),是否存在角化和附着的牙龈(“粘膜”),是否存在骨质流失>1.5 mm, 0.05)。基线和回忆得分之间没有统计学上的显著差异。所有FIT评分与临床成功相符,没有一个修复体被替换或修复。1年的成功率为100%。结论FIT是一种可行的、标准化的义齿治疗质量评价方法。两种材料在1年后显示相似的结果。需要更长的观测时间来证实这些初步结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Osseointegration
Journal of Osseointegration DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
0.90
自引率
25.00%
发文量
0
审稿时长
20 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信