Plain radiographic surveillance of abdominal aortic stent-grafts: the Liverpool/Perth protocol.

M. Murphy, R. Hodgson, P. Harris, R. McWilliams, D. Hartley, M. Lawrence-Brown
{"title":"Plain radiographic surveillance of abdominal aortic stent-grafts: the Liverpool/Perth protocol.","authors":"M. Murphy, R. Hodgson, P. Harris, R. McWilliams, D. Hartley, M. Lawrence-Brown","doi":"10.1583/1545-1550(2003)010<0911:PRSOAA>2.0.CO;2","DOIUrl":null,"url":null,"abstract":"PURPOSE\nTo present a protocol for plain radiographic surveillance of abdominal aortic stent-grafts that addresses the main variables in need of standardization: (1) patient position, (2) radiographic centering point, and (3) focus-to-film distance.\n\n\nTECHNIQUE\nOur policy is to perform baseline anteroposterior and lateral films following endoluminal grafting and repeat the studies annually. These are the most important films to assess migration and component separation; supplementary right and left posterior oblique radiographs may help identify wireform fractures. It is best to perform radiography before computed tomography if both tests are scheduled for the same day, as excretion of intravenous contrast opacifies the renal collecting systems and interferes with radiographic analysis.\n\n\nCONCLUSIONS\nEvaluation of the radiographs depends on the design of the stent-graft, so it is important to understand graft construction and the position of the radiopaque markers to best assess changes on follow-up films.","PeriodicalId":60152,"journal":{"name":"血管与腔内血管外科杂志","volume":"12 1","pages":"911-2"},"PeriodicalIF":0.0000,"publicationDate":"2003-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"54","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"血管与腔内血管外科杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1583/1545-1550(2003)010<0911:PRSOAA>2.0.CO;2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 54

Abstract

PURPOSE To present a protocol for plain radiographic surveillance of abdominal aortic stent-grafts that addresses the main variables in need of standardization: (1) patient position, (2) radiographic centering point, and (3) focus-to-film distance. TECHNIQUE Our policy is to perform baseline anteroposterior and lateral films following endoluminal grafting and repeat the studies annually. These are the most important films to assess migration and component separation; supplementary right and left posterior oblique radiographs may help identify wireform fractures. It is best to perform radiography before computed tomography if both tests are scheduled for the same day, as excretion of intravenous contrast opacifies the renal collecting systems and interferes with radiographic analysis. CONCLUSIONS Evaluation of the radiographs depends on the design of the stent-graft, so it is important to understand graft construction and the position of the radiopaque markers to best assess changes on follow-up films.
腹主动脉支架移植的x线平片监测:利物浦/珀斯方案。
目的提出一种腹主动脉支架移植的x线平片监测方案,该方案解决了需要标准化的主要变量:(1)患者体位,(2)x线摄影定心点,(3)焦点到膜的距离。我们的政策是在腔内植骨后进行基线正位和侧位片,并每年重复研究。这些是评估迁移和组分分离的最重要的薄膜;辅助右侧和左侧后斜x线片可帮助识别钢丝骨折。如果两项检查安排在同一天进行,最好在进行x线摄影检查之前进行,因为静脉造影剂的排泄会使肾收集系统混浊,干扰x线摄影分析。结论x线片的评价取决于支架的设计,因此了解支架的结构和不透射线标记的位置对于评估随访片的变化非常重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
947
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信