{"title":"OCCUPATIONAL RADIATION DOSE OF PERSONAL IN PEDIATRIC INTERVENTIONAL CARDIOLOGY","authors":"Kevser HIŞIROĞLU AYAR, E. Kam, D. Yaşar","doi":"10.30931/jetas.1147340","DOIUrl":null,"url":null,"abstract":"This study aimed to determine the effective doses of the cardiologist, nurses, and technical staff in the pediatric angiography laboratory during their diagnostic and therapeutic applications. This study is also to compare the radiation dose in the applications performed in the country with the effective doses exposed on a world scale. A total of 39 coronary angiography(CA)+percutaneous transluminal angioplasty(PTCA) methods were performed in the pediatric angiography laboratory during the study. The radiation dose received for each person in a single application was determined, and the total dose values were measured in the sequential applications. If the annual workload is taken into consideration, it is calculated that the person with a high workload may be exposed to a dose of 1384.7 μSv per year. Furthermore, from the total effective dose values, the doses per procedure were calculated to be in the range of 6.5 to 11.1 μSv. These results are consistent with the literature.","PeriodicalId":7757,"journal":{"name":"Anadolu University Journal of Science and Technology-A Applied Sciences and Engineering","volume":"5 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-04-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anadolu University Journal of Science and Technology-A Applied Sciences and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30931/jetas.1147340","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This study aimed to determine the effective doses of the cardiologist, nurses, and technical staff in the pediatric angiography laboratory during their diagnostic and therapeutic applications. This study is also to compare the radiation dose in the applications performed in the country with the effective doses exposed on a world scale. A total of 39 coronary angiography(CA)+percutaneous transluminal angioplasty(PTCA) methods were performed in the pediatric angiography laboratory during the study. The radiation dose received for each person in a single application was determined, and the total dose values were measured in the sequential applications. If the annual workload is taken into consideration, it is calculated that the person with a high workload may be exposed to a dose of 1384.7 μSv per year. Furthermore, from the total effective dose values, the doses per procedure were calculated to be in the range of 6.5 to 11.1 μSv. These results are consistent with the literature.