{"title":"Changes in the functionality of tear film and autorefractometry reading after instillations of artificial tear products of different viscosity","authors":"V. Brzheskiy, E. L. Efimova, M. Kopylova, P.V. Kocharina, A. Primak, V. Nikolaenko","doi":"10.32364/2311-7729-2021-21-4-200-204","DOIUrl":null,"url":null,"abstract":"Aim: to study the changes in the critical parameters of tear film stability and autorefractometry in patients with mild dry eye syndrome (DES) after instilling artificial tear products of different viscosity. Patients and Methods: thirty patients aged 23–70 with mild bilateral DES were examined using the Visionix VX120+Dry Eye multi-diagnostic unit equipped with the TF-Scan to fix and assess tear film stability and tear breakup time (TBUT). The critical refraction and tear film parameters were evaluated by keratometry, corneal topography, TBUT, and tear meniscus height measurements. Next, an artificial tear product was instilled, i.e., group 1 (14 patients, 28 eyes) received a 0.15% sodium hyaluronate-based preparation, and group 2 (16 patients, 32 eyes) received a 0.4% sodium hyaluronate-based preparation. The examination was repeated after 30 sec and 5 min. Controls were seven healthy individuals (14 eyes). Results: in DES, breaks in the tear film appeared earlier and affected greater corneal surface area. A \"Destabilized tear film area\" parameter of the Visionix VX120+Dry Eye contributed significantly to the knowledge of tear film functionality, thereby empowering the diagnostic armamentarium in DES. As early as 30 sec after instillation of both artificial tear preparations, breakup-free time tended to increase, while the area of tear film destabilization tended to reduce. After 5 min, this trend continued to increase, particularly after instilling 0.15% sodium hyaluronate-based preparation. At the same time, changes in keratometry readings (i.e., sphere and cylinder) and astigmatism axis orientation were reported. Corneal refractive power (more in the flattest axis) increased, in particular, after the instillations of 0.15% hyaluronic acid. The range of changes was 0.00–0.75 D for the sphere power, 0.00–0.50 D for the cylinder power, and 0–69 degrees for astigmatism axis orientation. Conclusions: our findings with the Visionix VX120+Dry Eye multi-diagnostic unit demonstrate a significant variation of autorefractometry readings in DES depending on the extent of ocular surface hydration. These phenomena raise questions about the accuracy of autorefractometry readings. Therefore, autorefractometry should be performed after normalizing tear film volume and stability. Keywords: dry eye syndrome, Visionix®, autorefractometry, tearscopy, the effect of artificial tears on results. For citation: Brzheskiy V.V., Efimova E.L., Kopylova M.A. et al. Changes in the functionality of tear film and autorefractometry reading after instillations of artificial tear products of different viscosity. Russian Journal of Clinical Ophthalmology. 2021;21(4):200–204 (in Russ.). DOI: 10.32364/2311-7729-2021-21-4-200-204.","PeriodicalId":36455,"journal":{"name":"Russian Journal of Clinical Ophthalmology","volume":"3 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Russian Journal of Clinical Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32364/2311-7729-2021-21-4-200-204","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: to study the changes in the critical parameters of tear film stability and autorefractometry in patients with mild dry eye syndrome (DES) after instilling artificial tear products of different viscosity. Patients and Methods: thirty patients aged 23–70 with mild bilateral DES were examined using the Visionix VX120+Dry Eye multi-diagnostic unit equipped with the TF-Scan to fix and assess tear film stability and tear breakup time (TBUT). The critical refraction and tear film parameters were evaluated by keratometry, corneal topography, TBUT, and tear meniscus height measurements. Next, an artificial tear product was instilled, i.e., group 1 (14 patients, 28 eyes) received a 0.15% sodium hyaluronate-based preparation, and group 2 (16 patients, 32 eyes) received a 0.4% sodium hyaluronate-based preparation. The examination was repeated after 30 sec and 5 min. Controls were seven healthy individuals (14 eyes). Results: in DES, breaks in the tear film appeared earlier and affected greater corneal surface area. A "Destabilized tear film area" parameter of the Visionix VX120+Dry Eye contributed significantly to the knowledge of tear film functionality, thereby empowering the diagnostic armamentarium in DES. As early as 30 sec after instillation of both artificial tear preparations, breakup-free time tended to increase, while the area of tear film destabilization tended to reduce. After 5 min, this trend continued to increase, particularly after instilling 0.15% sodium hyaluronate-based preparation. At the same time, changes in keratometry readings (i.e., sphere and cylinder) and astigmatism axis orientation were reported. Corneal refractive power (more in the flattest axis) increased, in particular, after the instillations of 0.15% hyaluronic acid. The range of changes was 0.00–0.75 D for the sphere power, 0.00–0.50 D for the cylinder power, and 0–69 degrees for astigmatism axis orientation. Conclusions: our findings with the Visionix VX120+Dry Eye multi-diagnostic unit demonstrate a significant variation of autorefractometry readings in DES depending on the extent of ocular surface hydration. These phenomena raise questions about the accuracy of autorefractometry readings. Therefore, autorefractometry should be performed after normalizing tear film volume and stability. Keywords: dry eye syndrome, Visionix®, autorefractometry, tearscopy, the effect of artificial tears on results. For citation: Brzheskiy V.V., Efimova E.L., Kopylova M.A. et al. Changes in the functionality of tear film and autorefractometry reading after instillations of artificial tear products of different viscosity. Russian Journal of Clinical Ophthalmology. 2021;21(4):200–204 (in Russ.). DOI: 10.32364/2311-7729-2021-21-4-200-204.
注入不同粘度的人工泪液后,泪膜功能及自折射读数的变化
目的:研究轻度干眼综合征(DES)患者滴注不同黏度的人工泪液后泪膜稳定性及自折射等关键参数的变化。患者和方法:30例年龄23-70岁的轻度双侧DES患者,使用Visionix VX120+干眼多诊断装置,配备tf扫描,固定和评估泪膜稳定性和泪液破裂时间(TBUT)。通过角膜测量、角膜地形图、TBUT和撕裂半月板高度测量来评估关键折射和泪膜参数。然后灌注人工泪液,即1组(14例,28眼)接受0.15%玻尿酸钠基制剂,2组(16例,32眼)接受0.4%玻尿酸钠基制剂。在30秒和5分钟后重复检查。对照组为7名健康个体(14只眼睛)。结果:DES患者泪膜破裂出现较早,影响角膜表面积较大。Visionix VX120+干眼的“不稳定泪膜面积”参数对泪膜功能的了解有重要贡献,从而增强了DES的诊断设备。早在两种人工泪液制剂注入后30秒,泪膜无破裂时间就有增加的趋势,而泪膜不稳定面积有减少的趋势。5分钟后,这一趋势继续增加,特别是在灌注0.15%透明质酸钠基制剂后。同时,报告了角膜度数(即球体和圆柱体)和散光轴方向的变化。特别是0.15%透明质酸注入后,角膜屈光度(在最平坦的轴上更多)增加。球体功率的变化范围为0.00-0.75 D,圆柱功率的变化范围为0.00-0.50 D,像散轴方向的变化范围为0-69°。结论:我们使用Visionix VX120+干眼多诊断装置的研究结果表明,根据眼表水合程度的不同,DES的自折射读数有显著变化。这些现象引起了对自动折射仪读数准确性的质疑。因此,应在泪膜体积和稳定性归一化后进行自折射测定。关键词:干眼综合征,Visionix®,自折射验光,泪液镜,人工泪液对结果的影响引证:Brzheskiy v.v., Efimova e.l., Kopylova M.A.等。注入不同粘度的人工泪液后,泪膜功能及自折射读数的变化。俄罗斯临床眼科杂志。2021;21(4):200-204(俄文)。DOI: 10.32364 / 2311-7729-2021-21-4-200-204。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.60
自引率
0.00%
发文量
21
审稿时长
20 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信