Limit Analyses of the Active Earth Pressure on Rigid Retaining Walls under Strip Loading on Backfills

N. Tallah, A. Mabrouki, A. Boulaouad, M. Khemissa, A. Bouaicha
{"title":"Limit Analyses of the Active Earth Pressure on Rigid Retaining Walls under Strip Loading on Backfills","authors":"N. Tallah, A. Mabrouki, A. Boulaouad, M. Khemissa, A. Bouaicha","doi":"10.18280/acsm.460104","DOIUrl":null,"url":null,"abstract":"Recent studies of retaining walls include experimental studies, numerical analysis and analytical models. Although active earth pressure against retaining structures has received much attention, the evaluation of active earth pressure of backfill when loaded by a strip foundation, has been slightly studied. This paper studies the effect of a strip load on the active pressure force and the distribution of the horizontal stresses on a rigid wall, using a finite element limit analysis. The strip loading is located at different distances from the vertical face of the wall. The OptumG2 code is used to analyze the effect of width of strip surcharge (soil-wall), interface friction angle and soil internal friction angle. New interesting results are demonstrated and presented here: the dependency of the active earth pressure coefficient on both position and width of the strip load, in one hand, and the effect of the internal friction angle of the soil, the soil-wall interface, and the position of the strip loading on the failure mechanism, in the other hand.","PeriodicalId":7877,"journal":{"name":"Annales de Chimie - Science des Matériaux","volume":"18 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annales de Chimie - Science des Matériaux","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18280/acsm.460104","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Recent studies of retaining walls include experimental studies, numerical analysis and analytical models. Although active earth pressure against retaining structures has received much attention, the evaluation of active earth pressure of backfill when loaded by a strip foundation, has been slightly studied. This paper studies the effect of a strip load on the active pressure force and the distribution of the horizontal stresses on a rigid wall, using a finite element limit analysis. The strip loading is located at different distances from the vertical face of the wall. The OptumG2 code is used to analyze the effect of width of strip surcharge (soil-wall), interface friction angle and soil internal friction angle. New interesting results are demonstrated and presented here: the dependency of the active earth pressure coefficient on both position and width of the strip load, in one hand, and the effect of the internal friction angle of the soil, the soil-wall interface, and the position of the strip loading on the failure mechanism, in the other hand.
填土条形荷载作用下刚性挡土墙主动土压力极限分析
最近对挡土墙的研究包括实验研究、数值分析和分析模型。虽然挡土结构的主动土压力受到了广泛的关注,但对条形基础荷载作用下充填体主动土压力的评价研究较少。本文采用有限元极限分析方法,研究了条形荷载对刚性壁面主动压力和水平应力分布的影响。条形荷载位于离壁垂直面不同距离处。采用OptumG2程序分析了条状堆填物宽度(土-墙)、界面摩擦角和土内摩擦角对土体结构的影响。本文展示并展示了一些有趣的新结果:一方面,主动土压力系数与条形荷载的位置和宽度有关;另一方面,土的内摩擦角、土-墙界面和条形荷载的位置对破坏机制的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信