O. Taubmann, M. Unberath, G. Lauritsch, S. Achenbach, A. Maier
{"title":"Spatio-temporally regularized 4-D cardiovascular C-arm CT reconstruction using a proximal algorithm","authors":"O. Taubmann, M. Unberath, G. Lauritsch, S. Achenbach, A. Maier","doi":"10.1109/ISBI.2017.7950466","DOIUrl":null,"url":null,"abstract":"Tomographic reconstruction of cardiovascular structures from rotational angiograms acquired with interventional C-arm devices is challenging due to cardiac motion. Gating strategies are widely used to reduce data inconsistency but come at the cost of angular undersampling. We employ a spatio-temporally regularized 4-D reconstruction model, which is solved using a proximal algorithm, to handle the substantial undersampling associated with a strict gating setup. In a numerical phantom study based on the CAVAREV framework, similarity to the ground truth is improved from 82.3% to 87.6%by this approach compared to a state-of-the-art motion compensation algorithm, whereas previous regularized methods evaluated on this phantom achieved results below 80%. We also show first image results for a clinical patient data set.","PeriodicalId":6547,"journal":{"name":"2017 IEEE 14th International Symposium on Biomedical Imaging (ISBI 2017)","volume":"26 1","pages":"52-55"},"PeriodicalIF":0.0000,"publicationDate":"2017-04-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE 14th International Symposium on Biomedical Imaging (ISBI 2017)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISBI.2017.7950466","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
Abstract
Tomographic reconstruction of cardiovascular structures from rotational angiograms acquired with interventional C-arm devices is challenging due to cardiac motion. Gating strategies are widely used to reduce data inconsistency but come at the cost of angular undersampling. We employ a spatio-temporally regularized 4-D reconstruction model, which is solved using a proximal algorithm, to handle the substantial undersampling associated with a strict gating setup. In a numerical phantom study based on the CAVAREV framework, similarity to the ground truth is improved from 82.3% to 87.6%by this approach compared to a state-of-the-art motion compensation algorithm, whereas previous regularized methods evaluated on this phantom achieved results below 80%. We also show first image results for a clinical patient data set.