{"title":"1. Introduction","authors":"P. Wong, R. Campbell, O. Jacobsen, B. Fehr","doi":"10.1093/jicru_ndx008","DOIUrl":null,"url":null,"abstract":"A small photon field is usually characterized by the following limitations to accurate dosimetry: (1) lack of lateral electron equilibrium; (2) obscuring of the primary photon source by the collimation system; and (3) the limitations of conventional broadfield detectors to accurately measure absorbed dose under small-field conditions. Small photon fields are used both for intensity-modulated radiation therapy (IMRT) (ICRU, 2010) and for stereotactic radiation therapy (SRT), which is discussed in the present report. Stereotaxy historically refers to the use of a 3dimensional (3D) coordinate system to localize intracranial targets. As of the time of publication of this report the concept of stereotactic treatment has been expanded to refer to the accurate and reproducible localization of the clinical target in space (i.e., at the mm level) and in time. SRT involves stereotactic localization techniques combined with delivery of multiple small photon fields in a few high-dose fractions, leading to a highly conformal dose delivery with steep dose gradients. Stereotactic localization techniques may include the use of relocatable rigid frames, image-guidance techniques, and other positioning tools. Stereotactic radiosurgery (SRS) is intracranial SRT delivered in a single fraction. Stereotactic body radiation therapy (SBRT) is the use of SRT for extracranial treatments. Other nomenclature such as SABR, which stands for stereotactic ablative (body) radiotherapy, is also used, but is not recommended by ICRU. In SRT techniques, a high dose per fraction is a prescribed absorbed dose to the target per treatment fraction. The dose is higher than what would be delivered using conventional radiation therapy in a similar situation. A “few fractions” refers to a number of fractions that is significantly lower than the number of fractions that would be delivered using conventional radiation therapy in the identical clinical situation (i.e., typically 25 fractions or more) in a non-palliative scenario. Fractionation protocols can range from a single fraction of over 180 Gy (Kooshkabadi et al., 2013) for functional indications to 12 fractions of 4.3 Gy (Ritter et al., 2009) in early prostate cancer. The therapeutic ratio is enhanced through delivery of highly conformal dose distributions with steep dose fall-off ensuring optimal dose in the target volume with minimal normal tissue irradiation. The scope of this report is to discuss spatially small photon beam delivery, including dosimetry, commissioning, and quality assurance as well as to recommend a framework for prescribing, recording, and reporting stereotactic radiotherapy. This report covers all pathologies eligible for stereotactic delivery (malignant and non-malignant). Note that other radiation therapy techniques may deliver a high dose per fraction in a well-defined target volume, such as, intra-operative radiation therapy or high dose rate brachytherapy (HDR-BT). These techniques are not discussed.","PeriodicalId":91344,"journal":{"name":"Journal of the ICRU","volume":"32 1","pages":"11 - 30"},"PeriodicalIF":0.0000,"publicationDate":"2014-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the ICRU","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/jicru_ndx008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A small photon field is usually characterized by the following limitations to accurate dosimetry: (1) lack of lateral electron equilibrium; (2) obscuring of the primary photon source by the collimation system; and (3) the limitations of conventional broadfield detectors to accurately measure absorbed dose under small-field conditions. Small photon fields are used both for intensity-modulated radiation therapy (IMRT) (ICRU, 2010) and for stereotactic radiation therapy (SRT), which is discussed in the present report. Stereotaxy historically refers to the use of a 3dimensional (3D) coordinate system to localize intracranial targets. As of the time of publication of this report the concept of stereotactic treatment has been expanded to refer to the accurate and reproducible localization of the clinical target in space (i.e., at the mm level) and in time. SRT involves stereotactic localization techniques combined with delivery of multiple small photon fields in a few high-dose fractions, leading to a highly conformal dose delivery with steep dose gradients. Stereotactic localization techniques may include the use of relocatable rigid frames, image-guidance techniques, and other positioning tools. Stereotactic radiosurgery (SRS) is intracranial SRT delivered in a single fraction. Stereotactic body radiation therapy (SBRT) is the use of SRT for extracranial treatments. Other nomenclature such as SABR, which stands for stereotactic ablative (body) radiotherapy, is also used, but is not recommended by ICRU. In SRT techniques, a high dose per fraction is a prescribed absorbed dose to the target per treatment fraction. The dose is higher than what would be delivered using conventional radiation therapy in a similar situation. A “few fractions” refers to a number of fractions that is significantly lower than the number of fractions that would be delivered using conventional radiation therapy in the identical clinical situation (i.e., typically 25 fractions or more) in a non-palliative scenario. Fractionation protocols can range from a single fraction of over 180 Gy (Kooshkabadi et al., 2013) for functional indications to 12 fractions of 4.3 Gy (Ritter et al., 2009) in early prostate cancer. The therapeutic ratio is enhanced through delivery of highly conformal dose distributions with steep dose fall-off ensuring optimal dose in the target volume with minimal normal tissue irradiation. The scope of this report is to discuss spatially small photon beam delivery, including dosimetry, commissioning, and quality assurance as well as to recommend a framework for prescribing, recording, and reporting stereotactic radiotherapy. This report covers all pathologies eligible for stereotactic delivery (malignant and non-malignant). Note that other radiation therapy techniques may deliver a high dose per fraction in a well-defined target volume, such as, intra-operative radiation therapy or high dose rate brachytherapy (HDR-BT). These techniques are not discussed.
1. 介绍
对于精确的剂量测定来说,小光子场通常有以下限制:(1)缺乏横向电子平衡;(2)准直系统对主光源的遮挡;(3)传统宽场探测器在小场条件下精确测量吸收剂量的局限性。小光子场用于调强放射治疗(IMRT) (ICRU, 2010)和立体定向放射治疗(SRT),这在本报告中进行了讨论。立体定位历来是指使用三维(3D)坐标系来定位颅内目标。在本报告发表时,立体定向治疗的概念已经扩展到指临床靶标在空间(即毫米水平)和时间上的准确和可重复定位。SRT涉及立体定向定位技术,结合在少数高剂量部分中递送多个小光子场,导致具有陡峭剂量梯度的高度适形剂量递送。立体定向定位技术可能包括使用可重新定位的刚性框架、图像引导技术和其他定位工具。立体定向放射外科手术(SRS)是一种以单一碎片形式进行的颅内SRT。立体定向放射治疗(SBRT)是利用立体定向放射治疗进行颅外治疗。也使用其他命名法,如SABR,它代表立体定向消融(身体)放疗,但ICRU不推荐使用。在SRT技术中,每个部分的高剂量是每个治疗部分对目标的规定吸收剂量。这种剂量比在类似情况下使用传统放射疗法的剂量要高。“少数部分”是指在相同的临床情况下(即,通常为25个或更多),在非姑息方案中,使用传统放射治疗将递送的部分数量明显低于部分数量的部分数量。分离方案的范围从功能适应症的单个超过180 Gy (Kooshkabadi et al., 2013)到早期前列腺癌的12个4.3 Gy (Ritter et al., 2009)。通过提供高度适形的剂量分布和陡的剂量衰减,确保以最小的正常组织照射在靶体积中获得最佳剂量,从而提高了治疗比率。本报告的范围是讨论空间小光子束传输,包括剂量学、调试和质量保证,以及推荐立体定向放疗的处方、记录和报告框架。本报告涵盖了所有符合立体定向分娩条件的病理(恶性和非恶性)。请注意,其他放射治疗技术可以在明确的靶体积内提供高剂量,例如术中放射治疗或高剂量率近距离放射治疗(HDR-BT)。这里不讨论这些技术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书