{"title":"The Repeatability, Reproducibility, and Correlation of the Schirmer Test: A Comparison of Open versus Closed Eye.","authors":"Eren Ekici, Cagatay Caglar, Esra Ün Akgümüş","doi":"10.3341/kjo.2022.0006","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare the repeatability and reproducibility of the Schirmer test (ST) without anesthesia when the eyes are open (STo) and closed (STc) in previously undiagnosed patients with suggestive symptoms of dry eye.</p><p><strong>Methods: </strong>In a comparative, observational series case study, 31 patients were included in the study. STo and STc were alternately applied for a total of six times. The ST was applied two times with the eyes open (S1) and closed (S2), respectively, by a single ophthalmologist. Then the ST was repeated four times with the eyes open (S3, S5) and closed (S4, S6), respectively, by a single nurse.</p><p><strong>Results: </strong>S1, S3, and S5 were 23.4, 23.7, and 23.3 mm, respectively. S2, S4, and S6 were 14.7, 15.6, and 16.6 mm, respectively. STc scores were found to be statistically lower than the STo's in general (right: t = 2.033, p = 0.048; left: t = 3.474, p = 0.004). There was no statistically significant difference in the scores of the three tests with open eyes: S1, S3, and S5 (p = 0.462). There was also no statistically significant difference in the scores of the three tests with closed eyes: S2, S4, and S6 (p = 0.05).</p><p><strong>Conclusions: </strong>Our study suggests that although administering the ST with the patient's eyes open produces higher readings than STc in patients with suggestive symptoms of dry eye, there was an acceptable reliability among tests performed open and closed. Moreover, intraexaminer reliability was higher than interexaminer reliability for both with the eyes open and closed.</p>","PeriodicalId":17883,"journal":{"name":"Korean Journal of Ophthalmology : KJO","volume":"163 1","pages":"306-312"},"PeriodicalIF":0.0000,"publicationDate":"2022-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9388899/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Journal of Ophthalmology : KJO","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3341/kjo.2022.0006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/5/6 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To compare the repeatability and reproducibility of the Schirmer test (ST) without anesthesia when the eyes are open (STo) and closed (STc) in previously undiagnosed patients with suggestive symptoms of dry eye.

Methods: In a comparative, observational series case study, 31 patients were included in the study. STo and STc were alternately applied for a total of six times. The ST was applied two times with the eyes open (S1) and closed (S2), respectively, by a single ophthalmologist. Then the ST was repeated four times with the eyes open (S3, S5) and closed (S4, S6), respectively, by a single nurse.

Results: S1, S3, and S5 were 23.4, 23.7, and 23.3 mm, respectively. S2, S4, and S6 were 14.7, 15.6, and 16.6 mm, respectively. STc scores were found to be statistically lower than the STo's in general (right: t = 2.033, p = 0.048; left: t = 3.474, p = 0.004). There was no statistically significant difference in the scores of the three tests with open eyes: S1, S3, and S5 (p = 0.462). There was also no statistically significant difference in the scores of the three tests with closed eyes: S2, S4, and S6 (p = 0.05).

Conclusions: Our study suggests that although administering the ST with the patient's eyes open produces higher readings than STc in patients with suggestive symptoms of dry eye, there was an acceptable reliability among tests performed open and closed. Moreover, intraexaminer reliability was higher than interexaminer reliability for both with the eyes open and closed.

Abstract Image

Schirmer试验的重复性、再现性和相关性:睁眼和闭眼的比较。
目的:比较未确诊的干眼症患者未麻醉时睁眼(STo)和闭眼(STc)时Schirmer试验(ST)的重复性和再现性。方法:采用比较观察系列病例研究,纳入31例患者。STo和STc交替申请共6次。ST分别在眼睛睁开(S1)和闭上(S2)的情况下由一名眼科医生应用两次。然后由一名护士分别在睁眼(S3, S5)和闭眼(S4, S6)的情况下重复4次ST。结果:S1、S3、S5分别为23.4、23.7、23.3 mm。S2、S4和S6分别为14.7、15.6和16.6 mm。STc组得分总体上低于STo组(右:t = 2.033, p = 0.048;左:t = 3.474, p = 0.004)。睁眼三项测试:S1、S3、S5得分比较,差异无统计学意义(p = 0.462)。闭眼时S2、S4、S6三项测试得分比较,差异无统计学意义(p = 0.05)。结论:我们的研究表明,尽管在有干眼症症状的患者睁着眼睛进行ST检测比STc检测产生更高的读数,但在开着和闭着进行的测试中,可靠性是可以接受的。此外,无论是睁眼还是闭眼,被测者内部的信度都高于被测者外部的信度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Korean Journal of Ophthalmology : KJO
Korean Journal of Ophthalmology : KJO Medicine-Ophthalmology
CiteScore
2.40
自引率
0.00%
发文量
84
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书