Mechanical behavior of implant-supported full-arch prostheses in different locations in the maxilla: 3D-FEA and strain gauge analysis

Q3 Dentistry
Mateus Favero Barra Grande, G. Lopes, M. Teixeira, A. Pelegrine, J. Matos, R. S. Nishioka
{"title":"Mechanical behavior of implant-supported full-arch prostheses in different\n locations in the maxilla: 3D-FEA and strain gauge analysis","authors":"Mateus Favero Barra Grande, G. Lopes, M. Teixeira, A. Pelegrine, J. Matos, R. S. Nishioka","doi":"10.4322/bds.2023.e3771","DOIUrl":null,"url":null,"abstract":"The maxillary bone restriction can limit the implants position to support a full-arch prosthesis. Objective: Therefore, this study evaluated the biomechanical behavior of a full-arch prosthesis supported by six implants in different configurations: group A (implants inserted in the region of canines, first premolars and second molars), group B (implants inserted in the region of first premolar, first molar and second molar) and group C (implants in second premolar, first premolar and second molar). Material and Methods: The models were analyzed by the finite element method validated by strain gauge. Three types of loads were applied: in the central incisors, first premolars and second molars, obtaining results of von-Mises stress peaks and microstrain. All registered results reported higher stress concentration in the prosthesis of all groups, with group C presenting higher values in all structures when compared to A and B groups. The highest mean microstrain was also observed in group C (288.8 ± 225.2 μ ε/ μ ε ), however, there was no statistically significant difference between the evaluated groups. In both groups, regardless of the magnitude and direction of the load, the maximum von-Mises stresses recorded for implants and prosthesis displacements were lower in group A. Conclusion: It was concluded that an equidistant distribution of implants favors biomechanical behavior of full-arch prostheses supported by implants; and the placement of posterior implants seems to be a viable alternative to rehabilitate totally edentulous individuals.","PeriodicalId":37577,"journal":{"name":"Brazilian Dental Science","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian Dental Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4322/bds.2023.e3771","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 2

Abstract

The maxillary bone restriction can limit the implants position to support a full-arch prosthesis. Objective: Therefore, this study evaluated the biomechanical behavior of a full-arch prosthesis supported by six implants in different configurations: group A (implants inserted in the region of canines, first premolars and second molars), group B (implants inserted in the region of first premolar, first molar and second molar) and group C (implants in second premolar, first premolar and second molar). Material and Methods: The models were analyzed by the finite element method validated by strain gauge. Three types of loads were applied: in the central incisors, first premolars and second molars, obtaining results of von-Mises stress peaks and microstrain. All registered results reported higher stress concentration in the prosthesis of all groups, with group C presenting higher values in all structures when compared to A and B groups. The highest mean microstrain was also observed in group C (288.8 ± 225.2 μ ε/ μ ε ), however, there was no statistically significant difference between the evaluated groups. In both groups, regardless of the magnitude and direction of the load, the maximum von-Mises stresses recorded for implants and prosthesis displacements were lower in group A. Conclusion: It was concluded that an equidistant distribution of implants favors biomechanical behavior of full-arch prostheses supported by implants; and the placement of posterior implants seems to be a viable alternative to rehabilitate totally edentulous individuals.
上颌骨不同位置种植体全弓修复体的力学行为:3D-FEA和应变仪分析
上颌骨的限制可以限制种植体的位置,以支持全弓假体。因此,本研究评估了a组(种植体在犬齿、第一前磨牙和第二磨牙区域)、B组(种植体在第一前磨牙、第一磨牙和第二磨牙区域)和C组(种植体在第二前磨牙、第一前磨牙和第二磨牙区域)六种不同配置的全弓假体的生物力学行为。材料与方法:采用应变片验证的有限元方法对模型进行分析。在中切牙、第一前磨牙和第二磨牙分别施加三种载荷,得到了von-Mises应力峰值和微应变的结果。所有记录的结果均显示,所有组假体的应力浓度均较高,与A和B组相比,C组所有结构的应力浓度均较高。C组平均微应变最高(288.8±225.2 μ ε/ μ ε),但各组间差异无统计学意义。在两组中,无论载荷的大小和方向如何,a组所记录的种植体最大von-Mises应力和假体位移均较低。结论:种植体的等距分布有利于种植体支撑全弓假体的生物力学行为;而后路种植体的安置似乎是一个可行的替代完全无牙个体的康复。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Brazilian Dental Science
Brazilian Dental Science Dentistry-Dentistry (all)
CiteScore
1.60
自引率
0.00%
发文量
75
审稿时长
16 weeks
期刊介绍: The Journal BRAZILIAN DENTAL SCIENCE is a trimonthly scientific publication of the Institute of Science and Technology of São José dos Campos - UNESP. MISSION - To disseminate and promote the interchange of scientific information amongst the national and international dental community, by means of basic and applied research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信