Intraneural stimulation using 2D wire-microelectrode arrays. I. Experimental results

J. Smit, W. Rutten
{"title":"Intraneural stimulation using 2D wire-microelectrode arrays. I. Experimental results","authors":"J. Smit, W. Rutten","doi":"10.1109/IEMBS.1995.579518","DOIUrl":null,"url":null,"abstract":"A two-dimensional 24-channel wire-microelectrode array was inserted into the peroneal nerve of the rat during acute experiments. The electrodes in the array are on a regular grid of 6 by 4 electrodes; inter-electrode spacing is 120 /spl mu/m. For each of the electrodes in the array the corresponding twitch-force recruitment curve was recorded from the extensor digitorum longus muscle (EDL). A complete set of 24 recruitment curves is presented The shape of the recruitment curves varies among the electrodes in the array. This supports previous findings which suggest a different motor unit recruitment order for stimulating electrodes at different intraneural positions.","PeriodicalId":20509,"journal":{"name":"Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1995-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMBS.1995.579518","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

A two-dimensional 24-channel wire-microelectrode array was inserted into the peroneal nerve of the rat during acute experiments. The electrodes in the array are on a regular grid of 6 by 4 electrodes; inter-electrode spacing is 120 /spl mu/m. For each of the electrodes in the array the corresponding twitch-force recruitment curve was recorded from the extensor digitorum longus muscle (EDL). A complete set of 24 recruitment curves is presented The shape of the recruitment curves varies among the electrodes in the array. This supports previous findings which suggest a different motor unit recruitment order for stimulating electrodes at different intraneural positions.
利用二维线微电极阵列进行神经内刺激。一、实验结果
在急性实验中,在大鼠腓神经内插入二维24通道线微电极阵列。阵列中的电极位于6 × 4电极的规则网格上;电极间距为120 /spl mu/m。对于阵列中的每个电极,记录了相应的指长伸肌(EDL)的抽搐力恢复曲线。得到了一套完整的24条招募曲线,这些曲线的形状在阵列中电极之间是不同的。这支持了先前的发现,即在不同的神经内位置刺激电极有不同的运动单元招募顺序。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信