Determination of nonionic polyethoxylate surfactants in wastewater and sludge samples of sewage treatment plants by liquid chromatography-mass spectrometry

Analusis Pub Date : 2000-07-01 DOI:10.1051/ANALUSIS:2000167
S. Chiron, E. Sauvard, R. Jeannot
{"title":"Determination of nonionic polyethoxylate surfactants in wastewater and sludge samples of sewage treatment plants by liquid chromatography-mass spectrometry","authors":"S. Chiron, E. Sauvard, R. Jeannot","doi":"10.1051/ANALUSIS:2000167","DOIUrl":null,"url":null,"abstract":"An analytical method is proposed in order to determine the major nonionic surfactants, octylphenolpolyethoxylates (OPEOs), nonylphenolpolyethoxylates (NPEOs) and aliphatic alcoholpolyethoxylates (AEOs), and their metabolites, nonylphenol and octylphenol in wastewater and sludge samples of sewage treatment plants. This method involved a Soxtec extraction step and a solid phase extraction step for the nonionic surfactant extraction from sludge and wastewater samples, respectively. Wit h both methodologies, all recovery values were higher than 70 %. Quantitation and identification of individual compound were car- ried out by liquid chromatography-mass spectrometry (LC/MS) using electrospray (ESP) as ionization mode. Reverse phase LC chromatography allowed the elution of all oligomer constituents of each homolog component into a single peak. Gathering all the oligomers into a single peak increased the peak intensity and provided a way to determine low concentration of APEOs and AEOs in different environmental matrices. Information on the oligomers distribution of APEOs and AEOs could be obtained by the extraction of selected m/z ions from the TIC chromatograms. Positive ESP LC/MS analyses of AEOs and APEOs yielded pri- mary pseudo-molecular ions of the (M + Na)+ type for each oligomer. The negative ionization mode allowed the determination of the two metabolites, nonylphenol and octylphenol, characterized by the pseudo molecular (M-H) - ion. Limits of detection achieved were 0.1 μg/L in wastewater sample and 10 ng/g in sludge samples. The developed LC-ESP/MS method was applied to the analysis of wastewater and sludge samples of two sewage treatment plants located in Orleans (France).","PeriodicalId":8221,"journal":{"name":"Analusis","volume":"50 1","pages":"535-542"},"PeriodicalIF":0.0000,"publicationDate":"2000-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"22","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analusis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1051/ANALUSIS:2000167","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 22

Abstract

An analytical method is proposed in order to determine the major nonionic surfactants, octylphenolpolyethoxylates (OPEOs), nonylphenolpolyethoxylates (NPEOs) and aliphatic alcoholpolyethoxylates (AEOs), and their metabolites, nonylphenol and octylphenol in wastewater and sludge samples of sewage treatment plants. This method involved a Soxtec extraction step and a solid phase extraction step for the nonionic surfactant extraction from sludge and wastewater samples, respectively. Wit h both methodologies, all recovery values were higher than 70 %. Quantitation and identification of individual compound were car- ried out by liquid chromatography-mass spectrometry (LC/MS) using electrospray (ESP) as ionization mode. Reverse phase LC chromatography allowed the elution of all oligomer constituents of each homolog component into a single peak. Gathering all the oligomers into a single peak increased the peak intensity and provided a way to determine low concentration of APEOs and AEOs in different environmental matrices. Information on the oligomers distribution of APEOs and AEOs could be obtained by the extraction of selected m/z ions from the TIC chromatograms. Positive ESP LC/MS analyses of AEOs and APEOs yielded pri- mary pseudo-molecular ions of the (M + Na)+ type for each oligomer. The negative ionization mode allowed the determination of the two metabolites, nonylphenol and octylphenol, characterized by the pseudo molecular (M-H) - ion. Limits of detection achieved were 0.1 μg/L in wastewater sample and 10 ng/g in sludge samples. The developed LC-ESP/MS method was applied to the analysis of wastewater and sludge samples of two sewage treatment plants located in Orleans (France).
液相色谱-质谱法测定污水处理厂废水和污泥样品中的非离子聚氧乙酸表面活性剂
提出了一种测定污水处理厂废水和污泥样品中主要非离子表面活性剂壬基酚聚氧基酸酯(OPEOs)、壬基酚聚氧基酸酯(NPEOs)和脂肪族醇聚氧基酸酯(AEOs)及其代谢产物壬基酚和辛基酚的分析方法。该方法采用Soxtec萃取步骤和固相萃取步骤,分别从污泥和废水样品中提取非离子表面活性剂。两种方法的回收率均大于70%。以电喷雾(ESP)为电离模式,采用液相色谱-质谱法(LC/MS)对单个化合物进行定量鉴定。反相LC色谱法允许将每个同源成分的所有低聚物成分洗脱成单个峰。将所有低聚物聚集在一个单峰中,增加了峰强度,为不同环境基质中低浓度的APEOs和AEOs的测定提供了一种方法。通过提取TIC色谱中选定的m/z离子,可以得到APEOs和AEOs的低聚物分布信息。对AEOs和APEOs进行ESP液相色谱/质谱分析,得到了多个(M + Na)+型的伪分子离子。负离子模式允许测定两种代谢物壬基酚和辛基酚,表征为伪分子(M-H) -离子。废水样品的检出限为0.1 μg/L,污泥样品的检出限为10 ng/g。将所开发的LC-ESP/MS方法应用于位于法国奥尔良的两个污水处理厂的废水和污泥样品的分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信