Benzene Exposure Assessment of Underground Storage Tank Contractors

W. H. Kramer
{"title":"Benzene Exposure Assessment of Underground Storage Tank Contractors","authors":"W. H. Kramer","doi":"10.1080/08828032.1989.10390652","DOIUrl":null,"url":null,"abstract":"Abstract Benzene and total hydrocarbon (as hexane) exposures were measured during removal, cleaning, pumping, and testing of underground gasoline storage tanks at five gasoline retail outlets in New Jersey during 1988. Personal air samples were collected using 3M 3500 Organic Vapor Monitors with sampling times ranging from 15 minutes to 6.5 hours. Benzene exposures to the observer ranged from 0.12 to 0.43 ppm (sampling times ranging from 4.75 to 6.5 hours). Benzene exposures to laborers during tank removal (including cutting and cleaning) ranged from 0.43 to 3.84 ppm (sampling times ranging from 1.5 to 6 hours). The highest short-term benzene exposure was 9.14 ppm (sampling time 15 minutes) for a tank cleaning assistant. Benzene exposures during tank cutting ranged from 2.16 to 4.57 ppm (sampling times ranged from 0.5 to 3 hours). Benzene exposure to a tank tester was 0.23 ppm (sampling time of 4.75 hours). Total hydrocarbons as hexane were also determined. The mean ratio of benezene to total hydrocarbon ...","PeriodicalId":8049,"journal":{"name":"Applied Industrial Hygiene","volume":"10 1","pages":"269-272"},"PeriodicalIF":0.0000,"publicationDate":"1989-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Industrial Hygiene","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/08828032.1989.10390652","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

Abstract

Abstract Benzene and total hydrocarbon (as hexane) exposures were measured during removal, cleaning, pumping, and testing of underground gasoline storage tanks at five gasoline retail outlets in New Jersey during 1988. Personal air samples were collected using 3M 3500 Organic Vapor Monitors with sampling times ranging from 15 minutes to 6.5 hours. Benzene exposures to the observer ranged from 0.12 to 0.43 ppm (sampling times ranging from 4.75 to 6.5 hours). Benzene exposures to laborers during tank removal (including cutting and cleaning) ranged from 0.43 to 3.84 ppm (sampling times ranging from 1.5 to 6 hours). The highest short-term benzene exposure was 9.14 ppm (sampling time 15 minutes) for a tank cleaning assistant. Benzene exposures during tank cutting ranged from 2.16 to 4.57 ppm (sampling times ranged from 0.5 to 3 hours). Benzene exposure to a tank tester was 0.23 ppm (sampling time of 4.75 hours). Total hydrocarbons as hexane were also determined. The mean ratio of benezene to total hydrocarbon ...
地下储罐承包商苯暴露评价
摘要1988年,对新泽西州5个汽油零售店的地下汽油储罐进行了拆除、清洗、泵送和测试,测量了苯和总碳氢化合物(如己烷)暴露量。使用3M 3500有机蒸汽监测仪采集个人空气样本,采样时间从15分钟到6.5小时不等。对观察者的苯暴露范围为0.12至0.43 ppm(采样时间范围为4.75至6.5小时)。在储罐拆除(包括切割和清洁)过程中,工人接触到的苯含量从0.43到3.84 ppm不等(采样时间从1.5到6小时不等)。对一名油罐清洁助手而言,短期苯暴露最高为9.14 ppm(采样时间15分钟)。在罐切割期间,苯暴露范围为2.16至4.57 ppm(采样时间范围为0.5至3小时)。苯暴露于罐式测试仪为0.23 ppm(采样时间为4.75小时)。同时测定了总碳氢化合物为己烷。苯与总烃的平均比值…
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信