{"title":"Experimental Performance Analysis of R1234yf in an Air-Conditioning System as Substitute of R134a","authors":"M. Medany, M. El Morsi, A. R. El-Sayed","doi":"10.1142/s201013252150036x","DOIUrl":null,"url":null,"abstract":"In this work, R1234yf is tested in an air-conditioning system as a proposed alternative to R134a. The system is tested at 30, 35, 40, 45 and 50[Formula: see text]Hz evaporator fan frequency to cool the air entering into the evaporator section at a fixed temperature of 35∘C. The system is charged with 600, 700, 800, 1000 and 1200[Formula: see text]g of each refrigerant. The charge mass of 800 grams gives the best performance for both refrigerants. Also, R1234yf has higher COP, exergetic efficiency, second law efficiency, and lower compressor power consumption. Both refrigerants operate at a moderate range of compressor discharge temperature of 85∘C.","PeriodicalId":13757,"journal":{"name":"International Journal of Air-conditioning and Refrigeration","volume":"76 9 1","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2021-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Air-conditioning and Refrigeration","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1142/s201013252150036x","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"THERMODYNAMICS","Score":null,"Total":0}
引用次数: 0

Abstract

In this work, R1234yf is tested in an air-conditioning system as a proposed alternative to R134a. The system is tested at 30, 35, 40, 45 and 50[Formula: see text]Hz evaporator fan frequency to cool the air entering into the evaporator section at a fixed temperature of 35∘C. The system is charged with 600, 700, 800, 1000 and 1200[Formula: see text]g of each refrigerant. The charge mass of 800 grams gives the best performance for both refrigerants. Also, R1234yf has higher COP, exergetic efficiency, second law efficiency, and lower compressor power consumption. Both refrigerants operate at a moderate range of compressor discharge temperature of 85∘C.
R1234yf替代R134a在空调系统中的试验性能分析
在这项工作中,R1234yf作为R134a的替代方案在空调系统中进行了测试。系统在30、35、40、45和50[公式:见原文]赫兹蒸发器风扇频率下进行测试,以在35°C的固定温度下冷却进入蒸发器段的空气。每种制冷剂分别充注600g、700g、800g、1000 g和1200 g[公式见文]。装药质量为800克时,两种制冷剂的性能最佳。此外,R1234yf具有更高的COP、火用效率、第二定律效率和更低的压缩机功耗。两种制冷剂在85°C的压缩机排气温度适中范围内工作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.70
自引率
10.00%
发文量
0
期刊介绍: As the only international journal in the field of air-conditioning and refrigeration in Asia, IJACR reports researches on the equipments for controlling indoor environment and cooling/refrigeration. It includes broad range of applications and underlying theories including fluid dynamics, thermodynamics, heat transfer, and nano/bio-related technologies. In addition, it covers future energy technologies, such as fuel cell, wind turbine, solar cell/heat, geothermal energy and etc.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信