Difficulties in choosing the right intraocular lens in a previously vitrectomized patient - the role of the tear film

Monica Mălăescu, Bogdana Tăbăcaru, H. Stanca
{"title":"Difficulties in choosing the right intraocular lens in a previously vitrectomized patient - the role of the tear film","authors":"Monica Mălăescu, Bogdana Tăbăcaru, H. Stanca","doi":"10.22336/rjo.2022.18","DOIUrl":null,"url":null,"abstract":"We present the difficulties in choosing the right IOL, when facing a great variability of the keratometric measurements, in the case of a patient operated for epiretinal membrane and lamellar macular hole, who developed complicated cataract in the operated eye. Upon commencing the biometric measurements, inconsistency in keratometric values led to further investigations. Repeated placido disc topography initially showed corneal ectasia, which posed a problem on selecting the right type of intra-ocular lens. Ocular surface pathology was suspected, and after treatment, the topography was repeated with a Scheimpflug topographer, that showed an improved keratometric profile. The surgical solution was to implant an aspheric monofocal IOL, in the bag, with extended depth of focus that enhances intermediate vision, disregarding the previous keratometric measurements. Refractive and functional outcomes were good. In cases of biometric measurements that show inconsistency in keratometric values, ocular surface disease as well as corneal ectasia should be taken into consideration. The right implant should not be chosen based on a single measurement, but rather several measurements should be made and compared and the choice should not be made before treating the ocular surface.","PeriodicalId":21385,"journal":{"name":"Romanian journal of ophthalmology","volume":"55 1","pages":"89 - 96"},"PeriodicalIF":0.0000,"publicationDate":"2022-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Romanian journal of ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22336/rjo.2022.18","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

We present the difficulties in choosing the right IOL, when facing a great variability of the keratometric measurements, in the case of a patient operated for epiretinal membrane and lamellar macular hole, who developed complicated cataract in the operated eye. Upon commencing the biometric measurements, inconsistency in keratometric values led to further investigations. Repeated placido disc topography initially showed corneal ectasia, which posed a problem on selecting the right type of intra-ocular lens. Ocular surface pathology was suspected, and after treatment, the topography was repeated with a Scheimpflug topographer, that showed an improved keratometric profile. The surgical solution was to implant an aspheric monofocal IOL, in the bag, with extended depth of focus that enhances intermediate vision, disregarding the previous keratometric measurements. Refractive and functional outcomes were good. In cases of biometric measurements that show inconsistency in keratometric values, ocular surface disease as well as corneal ectasia should be taken into consideration. The right implant should not be chosen based on a single measurement, but rather several measurements should be made and compared and the choice should not be made before treating the ocular surface.
玻璃体切除术患者选择合适人工晶体的困难-泪膜的作用
我们提出的困难,选择正确的人工晶状体时,面对很大的可变性角膜测量,在病人的情况下,视网膜前膜和板层黄斑孔手术,谁在手术眼并发白内障。在开始生物测量后,角膜测量值的不一致导致了进一步的研究。重复胎盘盘形貌最初表现为角膜扩张,这给选择合适的人工晶状体类型带来了问题。怀疑眼表病理,治疗后,用Scheimpflug地形仪重复地形,显示改善的角膜测量轮廓。手术解决方案是将非球面单焦点人工晶体(IOL)植入囊内,扩大聚焦深度,增强中间视力,而不考虑先前的角膜测量结果。屈光和功能结果良好。在角膜测量值不一致的情况下,应考虑眼表疾病和角膜扩张。正确的植入物不应该根据单一的测量来选择,而应该进行多次测量和比较,并且不应该在治疗眼表之前做出选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信