{"title":"DEVELOPING AND IMPLEMENTING THE QUALITY CONTROL PROGRAM ON A LINEAR ACCELERATOR","authors":"T. Antropova, K. Datbayev, E. Ishkinin, B. Latypova, O. Seitov, Z. Khudaibergenov","doi":"10.52532/2521-6414-2023-2-68-4-8","DOIUrl":null,"url":null,"abstract":"Relevance: The article deals with modern problems in the field of ensuring the quality of services provided on linear accelerators from the point of view of the regulatory framework, as well as from the point of view of the frequency of control procedures. The scientific novelty lies in elaborating a linear accelerator quality control program with detailed procedure descriptions and testing frequency recommendations. \nThe study aimed to – develop and test a set of simple methods for controlling the linear accelerator’s mechanical and dosimetric parameters, which would meet the minimum requirements for high-tech radiation therapy following IAEA and AAPM international recommendations. \nMethods: In developing the quality control program for the TrueBeamSTx linear accelerator (Varian, USA) installed at the Almaty Oncological Center (AOC, Kazakhstan), we relied on the recommendations of the International Atomic Energy Agency (IAEA) and the American Association of Physicists in Medicine (AAPM), taking into account that intensity-modulated radiotherapy (IMRT, VMAT), stereotactic radiosurgery and stereotactic radiotherapy (SRS, SRT), using image-guided radiation therapy (IGRT) will be performed on the accelerator, which imposes more stringent requirements for control of both mechanical and dosimetry characteristics \nResults: Over three years of operation, the TrueBeamSTx accelerator shows good stability of mechanical and dosimetric characteristics, verified using systematic tests according to the quality control program developed by the authors of this article. The IAEA/WHO mail dose monitoring program using radiophotoluminescent detectors, implemented in 2019-2022, showed high dosimetric measurements and calculations accuracy of 0.1-1.7%, at a tolerance of 5%. \nConclusion: A quality control program for a high-energy linear accelerator has been developed; the results obtained for all characteristics correspond to the permissible values. The effective and safe use of radiotherapy requires the development of a quality control program for all radiotherapy equipment specifically for each institution and independent verification of the implementation of this program.","PeriodicalId":19480,"journal":{"name":"Oncologia i radiologia Kazakhstana","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-06-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Oncologia i radiologia Kazakhstana","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52532/2521-6414-2023-2-68-4-8","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Relevance: The article deals with modern problems in the field of ensuring the quality of services provided on linear accelerators from the point of view of the regulatory framework, as well as from the point of view of the frequency of control procedures. The scientific novelty lies in elaborating a linear accelerator quality control program with detailed procedure descriptions and testing frequency recommendations. The study aimed to – develop and test a set of simple methods for controlling the linear accelerator’s mechanical and dosimetric parameters, which would meet the minimum requirements for high-tech radiation therapy following IAEA and AAPM international recommendations. Methods: In developing the quality control program for the TrueBeamSTx linear accelerator (Varian, USA) installed at the Almaty Oncological Center (AOC, Kazakhstan), we relied on the recommendations of the International Atomic Energy Agency (IAEA) and the American Association of Physicists in Medicine (AAPM), taking into account that intensity-modulated radiotherapy (IMRT, VMAT), stereotactic radiosurgery and stereotactic radiotherapy (SRS, SRT), using image-guided radiation therapy (IGRT) will be performed on the accelerator, which imposes more stringent requirements for control of both mechanical and dosimetry characteristics Results: Over three years of operation, the TrueBeamSTx accelerator shows good stability of mechanical and dosimetric characteristics, verified using systematic tests according to the quality control program developed by the authors of this article. The IAEA/WHO mail dose monitoring program using radiophotoluminescent detectors, implemented in 2019-2022, showed high dosimetric measurements and calculations accuracy of 0.1-1.7%, at a tolerance of 5%. Conclusion: A quality control program for a high-energy linear accelerator has been developed; the results obtained for all characteristics correspond to the permissible values. The effective and safe use of radiotherapy requires the development of a quality control program for all radiotherapy equipment specifically for each institution and independent verification of the implementation of this program.
制定和实施直线加速器的质量控制程序
相关性:本文从监管框架的角度以及从控制程序频率的角度处理确保线性加速器提供的服务质量领域的现代问题。其科学新颖之处在于制定了一套线性加速器质量控制方案,并对其进行了详细的程序描述和测试频率建议。这项研究的目的是开发和测试一套简单的方法来控制直线加速器的机械和剂量参数,这些方法将满足原子能机构和AAPM国际建议的高科技放射治疗的最低要求。方法:在为安装在阿拉木图肿瘤中心(AOC,哈萨克斯坦)的TrueBeamSTx直线加速器(Varian,美国)制定质量控制程序时,我们参考了国际原子能机构(IAEA)和美国医学物理学家协会(AAPM)的建议,同时考虑到调强放疗(IMRT, VMAT)、立体定向放射外科和立体定向放疗(SRS, SRT)、结果:经过三年的运行,TrueBeamSTx加速器显示出良好的机械和剂量特性稳定性,并根据本文作者制定的质量控制程序进行了系统测试。2019-2022年实施的原子能机构/世卫组织使用放射性光致发光探测器的邮件剂量监测方案显示,剂量学测量和计算精度为0.1-1.7%,容差为5%。结论:制定了高能直线加速器的质量控制方案;所得结果均符合允许值。放射治疗的有效和安全使用需要制定针对每个机构的所有放射治疗设备的质量控制程序,并对该程序的执行情况进行独立验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信