M. Lynch, F. R. Mosher, R. Schneider, H. Fouda, J. Risk
{"title":"Determination of carbadox-related residues in swine liver by gas chromatography/mass spectrometry with ion trap detection.","authors":"M. Lynch, F. R. Mosher, R. Schneider, H. Fouda, J. Risk","doi":"10.1093/JAOAC/74.4.611","DOIUrl":null,"url":null,"abstract":"The ion trap detector (ITD), in combination with a capillary gas chromatograph and under chemical ionization conditions, offers sufficient sensitivity to determine carbadox-related residues as the methyl ester derivative of quinoxaline-2-carboxylic acid at 3 micrograms/kg or higher in porcine liver. A tetradeuterated internal standard of QME effectively compensates for losses incurred during sample preparation. The method produced mean levels of 3.3 (+/- 0.5), 5.5 (+/- 0.8), and 10.1 (+/- 0.9) micrograms/kg for liver fortified at 3, 5, and 10 micrograms/kg. When applied to analysis of samples containing incurred residues of 14C-carbadox at the low microgram/kg level, results were comparable to those obtained by reverse isotope dilution analysis.","PeriodicalId":14752,"journal":{"name":"Journal - Association of Official Analytical Chemists","volume":"48 1","pages":"611-8"},"PeriodicalIF":0.0000,"publicationDate":"1991-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal - Association of Official Analytical Chemists","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/JAOAC/74.4.611","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10
Abstract
The ion trap detector (ITD), in combination with a capillary gas chromatograph and under chemical ionization conditions, offers sufficient sensitivity to determine carbadox-related residues as the methyl ester derivative of quinoxaline-2-carboxylic acid at 3 micrograms/kg or higher in porcine liver. A tetradeuterated internal standard of QME effectively compensates for losses incurred during sample preparation. The method produced mean levels of 3.3 (+/- 0.5), 5.5 (+/- 0.8), and 10.1 (+/- 0.9) micrograms/kg for liver fortified at 3, 5, and 10 micrograms/kg. When applied to analysis of samples containing incurred residues of 14C-carbadox at the low microgram/kg level, results were comparable to those obtained by reverse isotope dilution analysis.