P. Pandey, A. Pande, Smriti Mishra, D. Setya, A. Devra, V. Sinha, A. Bhatt
{"title":"Significance of Luminex-crossmatch assay and its mean fluorescence intensity - a retrospective observation in 380 renal transplant cases.","authors":"P. Pandey, A. Pande, Smriti Mishra, D. Setya, A. Devra, V. Sinha, A. Bhatt","doi":"10.5604/01.3001.0015.6985","DOIUrl":null,"url":null,"abstract":"Introduction: Cell-based complement-dependent cytotoxicity crossmatch (CDC-XM) and solid phase assays were introduced for assessing HLA antibodies. However, the complexity of data from cell-based and solid phase assays have led to potential confusion about how to use the results for clinical decision making. Aim: Aim of this study was to compare results of cell-based assay and solid phase assay, to evaluate the usefulness of L-XM for pretransplant detection of HLA class I and II donor-specific IgG antibodies, correlate the mean fluorescence intensity (MFI) values of class I and class II L-XM assay and with CDC-XM and L-PRA (panel reactive antibodies) results. Methods: In this retrospective study, 380 prospective renal transplant recipients were tested for the presence of HLA antibodies by CDC-XM, IgG-L-XM, IgG-L-PRA & L-SAB screening with their corresponding donor. Results: Fifty-one recipients (13.42%) had a positive CDC-XM. L-XM was positive in 125 recipients (32.89%); class I-L-XM was positive in 46 (36.80%) cases, and class II-L-XM was positive in 58 (46.4%) cases and 21 (16.8%) samples were positive for class I and class II. High background was present in 22 (5.87%) samples, the results of which were confirmed by retesting or by correlation with L-PRA and L-SAB assays. Conclusion: The introduction of more sensitive approaches for the detection of anti-HLA-IgG-antibodies, such as L-XM and L-PRA assay, has allowed the identification of anti-HLA-antibodies in recipient serum which is not usually identified by CDC-XM alone. However, L-XM has some limitations; they can be overcome if we combine this assay with L-PRA.","PeriodicalId":43422,"journal":{"name":"Polish Journal of Surgery","volume":"52 1","pages":"38-48"},"PeriodicalIF":0.6000,"publicationDate":"2022-04-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Polish Journal of Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5604/01.3001.0015.6985","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 3
Abstract
Introduction: Cell-based complement-dependent cytotoxicity crossmatch (CDC-XM) and solid phase assays were introduced for assessing HLA antibodies. However, the complexity of data from cell-based and solid phase assays have led to potential confusion about how to use the results for clinical decision making. Aim: Aim of this study was to compare results of cell-based assay and solid phase assay, to evaluate the usefulness of L-XM for pretransplant detection of HLA class I and II donor-specific IgG antibodies, correlate the mean fluorescence intensity (MFI) values of class I and class II L-XM assay and with CDC-XM and L-PRA (panel reactive antibodies) results. Methods: In this retrospective study, 380 prospective renal transplant recipients were tested for the presence of HLA antibodies by CDC-XM, IgG-L-XM, IgG-L-PRA & L-SAB screening with their corresponding donor. Results: Fifty-one recipients (13.42%) had a positive CDC-XM. L-XM was positive in 125 recipients (32.89%); class I-L-XM was positive in 46 (36.80%) cases, and class II-L-XM was positive in 58 (46.4%) cases and 21 (16.8%) samples were positive for class I and class II. High background was present in 22 (5.87%) samples, the results of which were confirmed by retesting or by correlation with L-PRA and L-SAB assays. Conclusion: The introduction of more sensitive approaches for the detection of anti-HLA-IgG-antibodies, such as L-XM and L-PRA assay, has allowed the identification of anti-HLA-antibodies in recipient serum which is not usually identified by CDC-XM alone. However, L-XM has some limitations; they can be overcome if we combine this assay with L-PRA.