Effect of heating–cooling regimes on the compressive strength of Alfa fiber Concrete

IF 1.3 Q3 CONSTRUCTION & BUILDING TECHNOLOGY
Zied Ben Hammed, H. Sabeur, M. B. Ouezdou
{"title":"Effect of heating–cooling regimes on the compressive strength of Alfa fiber Concrete","authors":"Zied Ben Hammed, H. Sabeur, M. B. Ouezdou","doi":"10.1680/jcoma.23.00022","DOIUrl":null,"url":null,"abstract":"In the first part of this research, concretes with different dosage on Alfa fibers were formulated. At ambient temperature, the results show that the incorporation of 1% per volume of concrete of untreated Alfa fiber represents the highest mechanical values among the Alfa fiber concretes. Further, the addition of Alfa fibers induces an increase in ductility, compared to no fiber concrete. In the second part, specimens of ordinary concrete, concrete with polypropylene fibers, with treated and untreated Alfa fibers are heated to various temperature plateaus up to 800°C, with an average heating rate 7- 8°C/min, in steps of 100°C, maintained for 3 h. At the end of these heating parts, two cooling regimes are applied: air and water cooling regimes. The impact of these heating-cooling regimes has been valued through the study of the residual compressive strength. For both regimes and for all types of fiber concretes, compressive strength drastically reduces, up to 800°C with linear tendencies. More damage is noticed in the case of fiber concrete quenched in the water. Furthermore, for both cooling regimes, the use of Alfa fibers allowed an improvement in the residual compressive strength of ordinary concrete and more particularly in the temperature range [500-800°C].","PeriodicalId":51787,"journal":{"name":"Proceedings of the Institution of Civil Engineers-Construction Materials","volume":"64 1","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2023-07-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Institution of Civil Engineers-Construction Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1680/jcoma.23.00022","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

In the first part of this research, concretes with different dosage on Alfa fibers were formulated. At ambient temperature, the results show that the incorporation of 1% per volume of concrete of untreated Alfa fiber represents the highest mechanical values among the Alfa fiber concretes. Further, the addition of Alfa fibers induces an increase in ductility, compared to no fiber concrete. In the second part, specimens of ordinary concrete, concrete with polypropylene fibers, with treated and untreated Alfa fibers are heated to various temperature plateaus up to 800°C, with an average heating rate 7- 8°C/min, in steps of 100°C, maintained for 3 h. At the end of these heating parts, two cooling regimes are applied: air and water cooling regimes. The impact of these heating-cooling regimes has been valued through the study of the residual compressive strength. For both regimes and for all types of fiber concretes, compressive strength drastically reduces, up to 800°C with linear tendencies. More damage is noticed in the case of fiber concrete quenched in the water. Furthermore, for both cooling regimes, the use of Alfa fibers allowed an improvement in the residual compressive strength of ordinary concrete and more particularly in the temperature range [500-800°C].
加热-冷却方式对阿尔法纤维混凝土抗压强度的影响
在本研究的第一部分中,配制了不同掺量的Alfa纤维混凝土。在常温下,未经处理的Alfa纤维掺入量为1% /体积时,其力学值最高。此外,与不添加纤维的混凝土相比,添加阿尔法纤维的混凝土延展性增加。在第二部分中,普通混凝土、聚丙烯纤维混凝土、经过处理和未经处理的阿尔法纤维试样被加热到高达800°C的各种温度平台,平均加热速率为7- 8°C/min,步骤为100°C,保持3小时。在这些加热部分结束时,采用两种冷却方式:空气和水冷却方式。通过对残余抗压强度的研究,对这些加热-冷却机制的影响进行了评估。对于这两种制度和所有类型的纤维混凝土,抗压强度急剧下降,高达800°C线性趋势。纤维混凝土在水中淬火时的破坏更为明显。此外,对于两种冷却机制,使用阿尔法纤维可以提高普通混凝土的残余抗压强度,特别是在温度范围[500-800°C]。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.80
自引率
0.00%
发文量
23
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信