{"title":"Magnitude Variation of Arterial Blood Pressure Measured Using Holo-Hilbert Spectral Analysis","authors":"Jia-Hua Lee, T. Hsiao, Chia-Chi Chang, H. Hsu","doi":"10.1142/S2424922X18500079","DOIUrl":null,"url":null,"abstract":"Arterial blood pressure (ABP) is one of the most crucial cardiovascular indicators in clinical practice. Hilbert–Huang transform (HHT) has been performed on ABP signals and resulted in ABP variability. The instantaneous P-wave interval variation had been further examined with baroreflex sensitivity. However, the instantaneous magnitude variation of ABP signal is still unclear with the pulse pressure (PP) variability. In 2016, Holo–Hilbert spectral analysis (HHSA) extended the HHT method for identifying the amplitude-modulated (AM) characteristics of signals. This method was applied to investigate the magnitude variation of ABP signal during different respiratory manipulations in this study. The results indicated that the AM parts were moderately correlated with PP series and corresponding respiratory patterns. The [Formula: see text]-values on PP series are [Formula: see text], and [Formula: see text] for spontaneous breathing, six-cycle breathing, and hyperventilation, respectively. The values on respiratory patterns are [Formula: see text], and [Formula: see text] for spontaneous breathing, six-cycle breathing, and hyperventilation, respectively. This study concludes that ABP signal with HHSA presents the corresponding PP series, the respiratory-related activities, and the respiratory effect on PP variability. This is the first demonstration of the magnitude variation of ABP signal and further research in this area is warranted.","PeriodicalId":47145,"journal":{"name":"Advances in Data Science and Adaptive Analysis","volume":"68 1","pages":"1850007:1-1850007:18"},"PeriodicalIF":0.5000,"publicationDate":"2018-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Data Science and Adaptive Analysis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1142/S2424922X18500079","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MATHEMATICS, INTERDISCIPLINARY APPLICATIONS","Score":null,"Total":0}
引用次数: 4

Abstract

Arterial blood pressure (ABP) is one of the most crucial cardiovascular indicators in clinical practice. Hilbert–Huang transform (HHT) has been performed on ABP signals and resulted in ABP variability. The instantaneous P-wave interval variation had been further examined with baroreflex sensitivity. However, the instantaneous magnitude variation of ABP signal is still unclear with the pulse pressure (PP) variability. In 2016, Holo–Hilbert spectral analysis (HHSA) extended the HHT method for identifying the amplitude-modulated (AM) characteristics of signals. This method was applied to investigate the magnitude variation of ABP signal during different respiratory manipulations in this study. The results indicated that the AM parts were moderately correlated with PP series and corresponding respiratory patterns. The [Formula: see text]-values on PP series are [Formula: see text], and [Formula: see text] for spontaneous breathing, six-cycle breathing, and hyperventilation, respectively. The values on respiratory patterns are [Formula: see text], and [Formula: see text] for spontaneous breathing, six-cycle breathing, and hyperventilation, respectively. This study concludes that ABP signal with HHSA presents the corresponding PP series, the respiratory-related activities, and the respiratory effect on PP variability. This is the first demonstration of the magnitude variation of ABP signal and further research in this area is warranted.
利用全息希尔伯特光谱分析测量动脉血压的幅度变化
动脉血压(ABP)是临床最重要的心血管指标之一。对ABP信号进行Hilbert-Huang变换(HHT),导致了ABP的可变性。用气压反射灵敏度进一步检测了瞬时纵波间隔变化。然而,ABP信号的瞬时幅度随脉压(PP)变异性的变化尚不清楚。2016年,Holo-Hilbert频谱分析(HHSA)扩展了HHT方法,用于识别信号的调幅(AM)特性。本研究采用该方法研究不同呼吸操作过程中ABP信号的幅度变化。结果表明,AM部分与PP系列和相应的呼吸模式中度相关。PP系列的[公式:见文]值分别为自发呼吸、六周期呼吸和超换气的[公式:见文]和[公式:见文]。自主呼吸、六周期呼吸和过度通气的呼吸模式值分别为[公式:见文]和[公式:见文]。本研究认为,与HHSA相关的ABP信号具有相应的PP序列、呼吸相关活性以及呼吸对PP变异性的影响。这是ABP信号幅度变化的首次证明,在这一领域的进一步研究是有必要的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Advances in Data Science and Adaptive Analysis
Advances in Data Science and Adaptive Analysis MATHEMATICS, INTERDISCIPLINARY APPLICATIONS-
自引率
0.00%
发文量
13
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信