Effect of Limb Rotation on Radiographic Measurements of Carpal Parameters in the Equine Carpus

H. Oheida, A. Anderson, M. Alrtib, H. Abushhiwa, S. Philip
{"title":"Effect of Limb Rotation on Radiographic Measurements of Carpal Parameters in the Equine Carpus","authors":"H. Oheida, A. Anderson, M. Alrtib, H. Abushhiwa, S. Philip","doi":"10.5455/jva.19700101120000","DOIUrl":null,"url":null,"abstract":"Radiography is an important diagnostic tool to evaluate limb deformities but is sensitive to changes in orientation of object, cassette or radiography machine. Influences of limb rotation on radiographic measurements of dorsopalmar carpal radiographs have not been reported. This study measured effects of limb rotations around vertical and horizontal axes on 10carpal parameters and identified an acceptable range of rotation where those parameters experienced a minimum change. Fifteen forelimbs from 9 adult equine cadavers were transected at the distal third of the radius, fixed vertically, then digitally radiographed 13 times. The first radiograph was aligned to a specific set of landmarks (ZDP) and subsequent radiographs were rotated through -15˚ to +15˚ in both axes with 5˚ intervals. Parameters were measured on the 195 radiographsand analysed using a random effects model. Percentage change for a 5˚ increase in rotation calculated as (slope x 5/absolute predicted value at zero degrees) x 100.Most of the parameters showed significant alterations during vertical and horizontal rotations. Using rotational angles of Vertical±5° and Horizontal±5° or 10° in only one axis as the maximum acceptable range of rotation from ZDP would offer the best potential to avoid significant effects of rotation on these measurements.","PeriodicalId":17430,"journal":{"name":"Journal of Veterinary Advances","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Veterinary Advances","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5455/jva.19700101120000","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Radiography is an important diagnostic tool to evaluate limb deformities but is sensitive to changes in orientation of object, cassette or radiography machine. Influences of limb rotation on radiographic measurements of dorsopalmar carpal radiographs have not been reported. This study measured effects of limb rotations around vertical and horizontal axes on 10carpal parameters and identified an acceptable range of rotation where those parameters experienced a minimum change. Fifteen forelimbs from 9 adult equine cadavers were transected at the distal third of the radius, fixed vertically, then digitally radiographed 13 times. The first radiograph was aligned to a specific set of landmarks (ZDP) and subsequent radiographs were rotated through -15˚ to +15˚ in both axes with 5˚ intervals. Parameters were measured on the 195 radiographsand analysed using a random effects model. Percentage change for a 5˚ increase in rotation calculated as (slope x 5/absolute predicted value at zero degrees) x 100.Most of the parameters showed significant alterations during vertical and horizontal rotations. Using rotational angles of Vertical±5° and Horizontal±5° or 10° in only one axis as the maximum acceptable range of rotation from ZDP would offer the best potential to avoid significant effects of rotation on these measurements.
肢体旋转对马腕骨参数x线测量的影响
x线摄影是评估肢体畸形的重要诊断工具,但对物体、盒或x线摄影机方向的变化很敏感。肢体旋转对腕背桡侧x线片测量的影响尚未见报道。本研究测量了沿垂直轴和水平轴旋转肢体对10个腕关节参数的影响,并确定了一个可接受的旋转范围,其中这些参数经历了最小的变化。从9具成年马尸体中取15具前肢,在桡骨远端三分之一处横切,垂直固定,然后进行数字x线摄影13次。第一张x线片对准一组特定的地标(ZDP),随后的x线片以5˚的间隔在两个轴上旋转-15˚至+15˚。测量了195张x光片的参数,并使用随机效应模型进行了分析。旋转增加5˚时的百分比变化计算为(斜率x 5/ 0度时的绝对预测值)x 100。在垂直和水平旋转过程中,大部分参数发生了显著变化。仅在一个轴上使用垂直±5°和水平±5°或10°的旋转角度作为ZDP的最大可接受旋转范围,将提供最佳潜力,以避免旋转对这些测量的显着影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信