5 Practical Consequences of the Introduction of the Recommended Operational Quantities

{"title":"5 Practical Consequences of the Introduction of the Recommended Operational Quantities","authors":"","doi":"10.1177/1473669120966215","DOIUrl":null,"url":null,"abstract":"The first two criteria are fulfilled by the definitions of the recommended quantities. The last criterion seems trivial but requires the availability of suitable instruments. The introduction of the recommended operational quantities for external radiation will have consequences for practical radiation protection. A comparison of the energy and angle dependence of the recommended fluence-to-dose, and kerma-todose, conversion coefficients with respect to those of the ICRU Report 39/51 operational quantities has been given in Subsection 4.4. Personal dosimeters and area monitoring instruments with a sensitivity reproducing exactly the energy and angle dependence of the ICRU Report 39/51 quantities would have had responses relative to what is needed for the recommended operational quantities equal to the ratios shown, and, therefore, generally, not be suitable to assess exactly the recommended operational quantities in this Report, except over limited energy ranges. In this section, an overview is given of the expected changes to radiation protection instrumentation and to their calibration to assess correctly the recommended quantities. For prospective radiation protection estimates with Monte Carlo programs, no difficulties are expected once the recommended conversion coefficients are introduced into the codes.","PeriodicalId":91344,"journal":{"name":"Journal of the ICRU","volume":"52 1","pages":"38 - 44"},"PeriodicalIF":0.0000,"publicationDate":"2020-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the ICRU","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/1473669120966215","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The first two criteria are fulfilled by the definitions of the recommended quantities. The last criterion seems trivial but requires the availability of suitable instruments. The introduction of the recommended operational quantities for external radiation will have consequences for practical radiation protection. A comparison of the energy and angle dependence of the recommended fluence-to-dose, and kerma-todose, conversion coefficients with respect to those of the ICRU Report 39/51 operational quantities has been given in Subsection 4.4. Personal dosimeters and area monitoring instruments with a sensitivity reproducing exactly the energy and angle dependence of the ICRU Report 39/51 quantities would have had responses relative to what is needed for the recommended operational quantities equal to the ratios shown, and, therefore, generally, not be suitable to assess exactly the recommended operational quantities in this Report, except over limited energy ranges. In this section, an overview is given of the expected changes to radiation protection instrumentation and to their calibration to assess correctly the recommended quantities. For prospective radiation protection estimates with Monte Carlo programs, no difficulties are expected once the recommended conversion coefficients are introduced into the codes.
5引入推荐操作数量的实际后果
推荐量的定义满足前两个标准。最后一个标准似乎微不足道,但需要有合适的工具。引入外部辐射的建议操作量将对实际的辐射防护产生影响。与ICRU第39/51号报告的操作量相比,建议的影响剂量换算系数和角对剂量换算系数与能量和角度的依赖关系的比较载于分节4.4。具有精确再现ICRU报告39/51数量的能量和角度依赖的灵敏度的个人剂量计和区域监测仪器的反应相对于建议操作数量所需的反应等于所示比率,因此,通常不适合准确评估本报告中建议的操作数量,除非在有限的能量范围内。本节概述辐射防护仪器及其校准的预期变化,以正确评估建议的数量。用蒙特卡罗程序进行预期辐射防护估计时,一旦将推荐的转换系数引入代码中,预计不会有任何困难。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信