Calculation of the Median Lethal Dose and Low Lethal Dose Using the CombiStats Biometric Software

P. V. Shadrin, T. A. Batuashvili, L. V. Simutenko, N. P. Neugodova
{"title":"Calculation of the Median Lethal Dose and Low Lethal Dose Using the CombiStats Biometric Software","authors":"P. V. Shadrin, T. A. Batuashvili, L. V. Simutenko, N. P. Neugodova","doi":"10.30895/1991-2919-2021-11-2-135-142","DOIUrl":null,"url":null,"abstract":"The median lethal dose (LD50) and low lethal dose (LD10) are calculated in acute toxicity studies, as well as during specific activity assessment of some medicines. The aim of the study was to develop a procedure for using CombiStats to calculate LD50 and LD10. The authors proposed a step-by-step algorithm for processing bioassay results using the CombiStats biometric software (median effective dose determination model, probit analysis) with conversion of doses to simple fractions (fractions of the maximum dose) to calculate LD50 and LD10. They compared LD50 and LD10 calculation results obtained using CombiStats with those obtained using electronic spreadsheets according to the Bliss–Miller–Tainter–Prozorovsky method described in the State Pharmacopoeia of the Russian Federation (General Monograph 1.1.0014.15). It has been demonstrated that the use of CombiStats sometimes has advantages over the use of the pharmacoepoeial method.","PeriodicalId":22286,"journal":{"name":"The Bulletin of the Scientific Centre for Expert Evaluation of Medicinal Products","volume":"719 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Bulletin of the Scientific Centre for Expert Evaluation of Medicinal Products","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30895/1991-2919-2021-11-2-135-142","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The median lethal dose (LD50) and low lethal dose (LD10) are calculated in acute toxicity studies, as well as during specific activity assessment of some medicines. The aim of the study was to develop a procedure for using CombiStats to calculate LD50 and LD10. The authors proposed a step-by-step algorithm for processing bioassay results using the CombiStats biometric software (median effective dose determination model, probit analysis) with conversion of doses to simple fractions (fractions of the maximum dose) to calculate LD50 and LD10. They compared LD50 and LD10 calculation results obtained using CombiStats with those obtained using electronic spreadsheets according to the Bliss–Miller–Tainter–Prozorovsky method described in the State Pharmacopoeia of the Russian Federation (General Monograph 1.1.0014.15). It has been demonstrated that the use of CombiStats sometimes has advantages over the use of the pharmacoepoeial method.
使用CombiStats生物计量软件计算中位致死剂量和低致死剂量
中位致死剂量(LD50)和低致死剂量(LD10)是在急性毒性研究中以及在某些药物的特定活性评估中计算的。本研究的目的是开发一种使用CombiStats计算LD50和LD10的程序。作者提出了使用CombiStats生物识别软件(中位有效剂量确定模型,概率分析)逐步处理生物测定结果的算法,并将剂量转换为简单分数(最大剂量的分数)来计算LD50和LD10。他们比较了使用CombiStats获得的LD50和LD10计算结果与根据俄罗斯联邦国家药典(General Monograph 1.1.0014.15)中描述的Bliss-Miller-Tainter-Prozorovsky方法使用电子表格获得的LD50和LD10计算结果。已经证明,使用CombiStats有时比使用药典方法具有优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信