Performance of electronic flow rate meters used for calibration of air sampling pumps.

P. Middendorf, D. Macintosh, L. V. Tow, P. L. Williams
{"title":"Performance of electronic flow rate meters used for calibration of air sampling pumps.","authors":"P. Middendorf, D. Macintosh, L. V. Tow, P. L. Williams","doi":"10.1080/15298660108984649","DOIUrl":null,"url":null,"abstract":"Electronic flow rate meters (EFRMs) have been used by industrial hygienists for more than 20 years and are useful because they reduce the time required to calibrate air sampling pumps. This study compared the variability of the traditional bubble burette meter with electronic flow meters and simultaneously compared several EFRMs under different calibration conditions. The flow rates of air sampling pumps were set using a standard bubble burette meter at flow rates of 2 or 50 mL/min using two pressure drops, 2 inches water and 10 inches water. Four airflow rate meters (Bios DryCal, A.P. Buck mini-Buck, MSA Accuflow, and Sensidyne Gilibrator) were concurrently compared at each of the pump flow rate and pressure drop combinations. Results indicated that the standard bubble burette method is more variable than the EFRMs and that the flow rates given by the EFRMs were significantly different (p<0.0001) at both the high and low flow rates. Although the calibrators gave significantly different flow rates, the difference was within the acceptable air sampling pump error of +/- 5%.","PeriodicalId":7449,"journal":{"name":"AIHAJ : a journal for the science of occupational and environmental health and safety","volume":"101 1","pages":"472-6"},"PeriodicalIF":0.0000,"publicationDate":"2001-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"AIHAJ : a journal for the science of occupational and environmental health and safety","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/15298660108984649","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Electronic flow rate meters (EFRMs) have been used by industrial hygienists for more than 20 years and are useful because they reduce the time required to calibrate air sampling pumps. This study compared the variability of the traditional bubble burette meter with electronic flow meters and simultaneously compared several EFRMs under different calibration conditions. The flow rates of air sampling pumps were set using a standard bubble burette meter at flow rates of 2 or 50 mL/min using two pressure drops, 2 inches water and 10 inches water. Four airflow rate meters (Bios DryCal, A.P. Buck mini-Buck, MSA Accuflow, and Sensidyne Gilibrator) were concurrently compared at each of the pump flow rate and pressure drop combinations. Results indicated that the standard bubble burette method is more variable than the EFRMs and that the flow rates given by the EFRMs were significantly different (p<0.0001) at both the high and low flow rates. Although the calibrators gave significantly different flow rates, the difference was within the acceptable air sampling pump error of +/- 5%.
用于校准空气取样泵的电子流量计的性能。
电子流量计(EFRMs)已经被工业卫生学家使用了20多年,因为它们减少了校准空气采样泵所需的时间,所以很有用。本研究比较了传统气泡滴管流量计与电子流量计的变异性,同时比较了几种不同校准条件下的EFRMs。空气取样泵的流量使用标准的气泡滴管流量计设置,流速为2或50 mL/min,使用两个压降,2英寸水和10英寸水。同时比较了四种流速计(Bios DryCal, A.P. Buck mini-Buck, MSA Accuflow和Sensidyne Gilibrator)在每种泵流量和压降组合下的性能。结果表明,与EFRMs相比,标准气泡滴管法的变化更大,在高、低流速下,EFRMs给出的流速差异显著(p<0.0001)。虽然校准器给出了显著不同的流量,但差异在可接受的空气采样泵误差+/- 5%之内。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信