Diana A. Toriz-Gutiérrez, H. Ramírez-Gasca, Luis E. Cárdenas-Galindo, E. Gallegos-Arellano
{"title":"Electrochemical Measurement System for Chlorides in Drinking and Wastewater","authors":"Diana A. Toriz-Gutiérrez, H. Ramírez-Gasca, Luis E. Cárdenas-Galindo, E. Gallegos-Arellano","doi":"10.3390/chemproc2021005046","DOIUrl":null,"url":null,"abstract":"This paper presents a system for the measurement of chlorides in drinking and wastewater, based on an electrochemical process using a selective electrode as a transducer, which was developed by this group. The measurement for the concentration is carried out by introducing the implemented electrode (considered as reference) in the sample that will be analyzed; then a current is passed producing a potential difference in the system. Different aqueous solutions of sodium chloride (NaCl) were used, ranging between 35 and 3546 µg of chloride ions (Cl−). As a data acquisition and monitoring system for the analysis, an ATmega 328P microcontroller was used as the main capture element for subsequent interpretation through graphics. The experimental results show that it was possible to detect a potential difference in the electrochemical measurement system that corresponded to 35 µg of chloride ions (Cl−), making clear the detection process and the selectivity of chloride ions. It is important to mention that with this measurement system and the applied methodology, results are obtained in real time using a small sample volume and without generate ng extra liquid waste, compared to the application of the traditional analytical titrimetric method. Finally, this chloride measurement system is inexpensive and can be used in drinking and wastewater measurements.","PeriodicalId":9815,"journal":{"name":"Chemistry Proceedings","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-12-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chemistry Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/chemproc2021005046","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This paper presents a system for the measurement of chlorides in drinking and wastewater, based on an electrochemical process using a selective electrode as a transducer, which was developed by this group. The measurement for the concentration is carried out by introducing the implemented electrode (considered as reference) in the sample that will be analyzed; then a current is passed producing a potential difference in the system. Different aqueous solutions of sodium chloride (NaCl) were used, ranging between 35 and 3546 µg of chloride ions (Cl−). As a data acquisition and monitoring system for the analysis, an ATmega 328P microcontroller was used as the main capture element for subsequent interpretation through graphics. The experimental results show that it was possible to detect a potential difference in the electrochemical measurement system that corresponded to 35 µg of chloride ions (Cl−), making clear the detection process and the selectivity of chloride ions. It is important to mention that with this measurement system and the applied methodology, results are obtained in real time using a small sample volume and without generate ng extra liquid waste, compared to the application of the traditional analytical titrimetric method. Finally, this chloride measurement system is inexpensive and can be used in drinking and wastewater measurements.