{"title":"Non-invasive confirmation of the identity of tablets by near-infrared spectroscopy","authors":"M. Ulmschneider, E. Penigault","doi":"10.1051/ANALUSIS:2000124","DOIUrl":null,"url":null,"abstract":"Calibration of non-invasive near-infrared (NIR) analysis for measurements in diffuse reflectance and transmittance was conducted to confirm the identity of different film-coated and uncoated tablets. NIR-spectra of both sides of the intact tablet s were recorded in diffuse reflectance. The second derivation of the spectra was computed and spectral matching was calibrated. A restricted wavelength range was proposed to recognize the tablets independently of the presentation over the NIR-light beam. For transmittance measurement, the tablets were arranged in groups according to their similarities. All calibrations were teste d against an independent set of sample spectra. The NIR-method proved to be fast and effective. Key-words. Fourier transform near-infrared spectroscopy - diffuse reflectance - transmittance - non-invasive tablets analysis - identity testing.","PeriodicalId":8221,"journal":{"name":"Analusis","volume":"123 1","pages":"336-346"},"PeriodicalIF":0.0000,"publicationDate":"2000-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analusis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1051/ANALUSIS:2000124","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6
Abstract
Calibration of non-invasive near-infrared (NIR) analysis for measurements in diffuse reflectance and transmittance was conducted to confirm the identity of different film-coated and uncoated tablets. NIR-spectra of both sides of the intact tablet s were recorded in diffuse reflectance. The second derivation of the spectra was computed and spectral matching was calibrated. A restricted wavelength range was proposed to recognize the tablets independently of the presentation over the NIR-light beam. For transmittance measurement, the tablets were arranged in groups according to their similarities. All calibrations were teste d against an independent set of sample spectra. The NIR-method proved to be fast and effective. Key-words. Fourier transform near-infrared spectroscopy - diffuse reflectance - transmittance - non-invasive tablets analysis - identity testing.