{"title":"Reconstruction and error detection of blood vessel network from ultrasound volume data","authors":"K. Masuda, A. Bossard, Yuki Sugano, Toshikazu Kato, S. Onogi","doi":"10.1109/CBMS.2013.6627850","DOIUrl":null,"url":null,"abstract":"Recently, we described a reconstruction method of the blood vessel network by 3D thinning to detect vessels bifurcations, which is applied to the control of microbubbles in vivo. However, that method did not include error detections and was only verified on a very simply shaped artificial blood vessel. In this paper we propose a system including an abstraction method for the blood vessel network. Such a model is then analyzed through graph theory and error patterns in the reconstructed network. We proceeded in vitro by acquiring volume data from an artificial capillary with multi-bifurcations whose diameter ranges from 0.5 to 2.0mm and with different flow velocities. We were able to reconstruct the blood vessel network of an in vitro artificial capillary with multi-bifurcations. Results show that our system successfully reconstructed the corresponding networks as much as the limitation of resolution of echography.","PeriodicalId":20519,"journal":{"name":"Proceedings of the 26th IEEE International Symposium on Computer-Based Medical Systems","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2013-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 26th IEEE International Symposium on Computer-Based Medical Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CBMS.2013.6627850","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Recently, we described a reconstruction method of the blood vessel network by 3D thinning to detect vessels bifurcations, which is applied to the control of microbubbles in vivo. However, that method did not include error detections and was only verified on a very simply shaped artificial blood vessel. In this paper we propose a system including an abstraction method for the blood vessel network. Such a model is then analyzed through graph theory and error patterns in the reconstructed network. We proceeded in vitro by acquiring volume data from an artificial capillary with multi-bifurcations whose diameter ranges from 0.5 to 2.0mm and with different flow velocities. We were able to reconstruct the blood vessel network of an in vitro artificial capillary with multi-bifurcations. Results show that our system successfully reconstructed the corresponding networks as much as the limitation of resolution of echography.
基于超声容积数据的血管网络重建与误差检测
最近,我们描述了一种通过三维细化血管网络来检测血管分叉的重建方法,并将其应用于体内微泡的控制。然而,这种方法不包括错误检测,并且只在形状非常简单的人造血管上进行了验证。本文提出了一个包含血管网络抽象方法的系统。然后利用图论和重构网络中的误差模式对该模型进行分析。在体外实验中,我们获取了直径为0.5 ~ 2.0mm、不同流速的多分叉人工毛细血管的体积数据。我们能够重建具有多分支的体外人工毛细血管的血管网络。结果表明,该系统在不受超声分辨率限制的情况下,成功地重建了相应的网络。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.10
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信