{"title":"Anions Bioremediation Potential of Immobilized Bacteria in Tannery Industrial Effluents from Kano State, Nigeria","authors":"A. Baba, S. Garba, H. Abdullahi, D. Baba","doi":"10.22034/CRL.2020.244405.1078","DOIUrl":null,"url":null,"abstract":"The present study aims to assess the potentials of immobilized bacteria in the remediation of anions within the effluents by determining the levels of the anions before and after the remediation. Industrial Effluents Samples from Gashash Tanneries (TAN1), Larabee Tannery Industry (TAN2) and Z Tannery Industries (TAN3) in Kano State, Nigeria were collected monthly for six months (August 2017 to January 2018). Bacteria were isolated from the effluents and immobilized on agar-agar. The effluent samples were analyzed for the anions before and after the treatment using DR/2010 HACH portable data logging spectrophotometer. Different masses (5 g, 10 g, 15 g, 20 g, and 25 g) of the bacteria were used in the treatment of 250 ml of the effluents for ten days in a shaker incubator (Gallenkamp-OC-4364-L) at the temperature 30 °C and speed of 60 rpm. Pre-treatment analysis of the effluents for nitrate (NO-3), Sulphate (SO2-4), Phosphate (PO3-4) and Chloride (Cl-) give the following results; NO-3 ranged (25.35±17.16-28.12±10.72 mg/l); SO2-4 (67.00±5.93-114.83±53.20 mg/l); PO3-4 (26.16±22.93-34.17±16.73 mg/l) and Cl- (22.57±9.64-26.00a±4.86 mg/l). No statistical difference (p ≤ 0.05) was observed for all the anions among the different industries. The bacterial isolates were identified as Neisseria spp, Bacillus cereus, and Staphylococcus aureus, in TAN1, TAN2, and TAN3, respectively. After treatment of the effluents with the different masses of the isolated bacteria, the mean level of NO-3 were found to range as (6.17±6.67-20.78±7.76); SO2-4 (25.73±17.84-46.00±46.81); PO3-4 (11.45±12.02-28.19±9.09) and Cl-(0.38±1.83-15.36±13.58). The results of Post-treatment analysis showed that there is an overall decrease in the levels of the anions determined when compared with that of the pre-treatment. The overall percentage reduction of the immobilized bacteria in the treatment of the respective effluents was in the order TAN3 (57%)>TAN1 (49%)>TAN2 (47%). Therefore, the immobilized bacteria are having higher potentials for the treatment of the anions in the effluents.","PeriodicalId":10686,"journal":{"name":"College & Research Libraries","volume":"419 1","pages":"43-53"},"PeriodicalIF":1.4000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"College & Research Libraries","FirstCategoryId":"91","ListUrlMain":"https://doi.org/10.22034/CRL.2020.244405.1078","RegionNum":3,"RegionCategory":"管理学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"INFORMATION SCIENCE & LIBRARY SCIENCE","Score":null,"Total":0}
引用次数: 3
Abstract
The present study aims to assess the potentials of immobilized bacteria in the remediation of anions within the effluents by determining the levels of the anions before and after the remediation. Industrial Effluents Samples from Gashash Tanneries (TAN1), Larabee Tannery Industry (TAN2) and Z Tannery Industries (TAN3) in Kano State, Nigeria were collected monthly for six months (August 2017 to January 2018). Bacteria were isolated from the effluents and immobilized on agar-agar. The effluent samples were analyzed for the anions before and after the treatment using DR/2010 HACH portable data logging spectrophotometer. Different masses (5 g, 10 g, 15 g, 20 g, and 25 g) of the bacteria were used in the treatment of 250 ml of the effluents for ten days in a shaker incubator (Gallenkamp-OC-4364-L) at the temperature 30 °C and speed of 60 rpm. Pre-treatment analysis of the effluents for nitrate (NO-3), Sulphate (SO2-4), Phosphate (PO3-4) and Chloride (Cl-) give the following results; NO-3 ranged (25.35±17.16-28.12±10.72 mg/l); SO2-4 (67.00±5.93-114.83±53.20 mg/l); PO3-4 (26.16±22.93-34.17±16.73 mg/l) and Cl- (22.57±9.64-26.00a±4.86 mg/l). No statistical difference (p ≤ 0.05) was observed for all the anions among the different industries. The bacterial isolates were identified as Neisseria spp, Bacillus cereus, and Staphylococcus aureus, in TAN1, TAN2, and TAN3, respectively. After treatment of the effluents with the different masses of the isolated bacteria, the mean level of NO-3 were found to range as (6.17±6.67-20.78±7.76); SO2-4 (25.73±17.84-46.00±46.81); PO3-4 (11.45±12.02-28.19±9.09) and Cl-(0.38±1.83-15.36±13.58). The results of Post-treatment analysis showed that there is an overall decrease in the levels of the anions determined when compared with that of the pre-treatment. The overall percentage reduction of the immobilized bacteria in the treatment of the respective effluents was in the order TAN3 (57%)>TAN1 (49%)>TAN2 (47%). Therefore, the immobilized bacteria are having higher potentials for the treatment of the anions in the effluents.
期刊介绍:
College & Research Libraries (C&RL) is the official scholarly research journal of the Association of College & Research Libraries, a division of the American Library Association, 50 East Huron St., Chicago, IL 60611. C&RL is a bimonthly, online-only publication highlighting a new C&RL study with a free, live, expert panel comprised of the study''s authors and additional subject experts.