{"title":"Using a titanium mesh plate to reconstruct the orbital floor after an incompletely reduced zygomaticomaxillary complex fracture.","authors":"H. Z. Wang, S. Lai, C. H. Chang","doi":"10.6452/KJMS.199506.0359","DOIUrl":null,"url":null,"abstract":"A 30 year-old male came to us for correcting his severe left enophthalmos five months after a facial trauma in a traffic accident. CT scan of his left orbit showed a greatly increased orbital volume, which was resulted from the incomplete reduction of left zygomaticomaxillary complex (ZMC) fracture, unrepaired medial and lateral walls, and improper restoration of the orbital floor with a silicone sheet. Also, the decreased ocular volume, due to the evisceration of the ruptured eyeball with intraocular silicone ball implantation, contributed to the patient's enophthalmos. Because the patient refused any kind of osteotomy for his incompletely reduced and malunion ZMC fracture in the procedures of orbital reconstruction, correction of his severe enophthalmos became very difficult if not impossible. Therefore, we used a piece of titanium mesh plate about 2.5 x 4 cm in size, and folded it into an L shape. The shorter part of the L-shaped plate was used to fix the whole plate by screwing it into the anterior surface of the inferior orbital rim. The longer part of the plate was used as a new orbital floor. To hold and push the intraocular implant upward and anteriorly, the longer part of the plate was adjusted to a level higher than the original floor level, and was bent upward gently in the posterior part. Postoperatively, the severe enophthalmos was markedly improved, and the patient was satisfied although an evident supratarsal sulcus was still present. After a follow-up of 18 months, no complication of migration, infection, or extrusion of the titanium mesh plate occurred.","PeriodicalId":12495,"journal":{"name":"Gaoxiong yi xue ke xue za zhi = The Kaohsiung journal of medical sciences","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1995-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Gaoxiong yi xue ke xue za zhi = The Kaohsiung journal of medical sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.6452/KJMS.199506.0359","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
A 30 year-old male came to us for correcting his severe left enophthalmos five months after a facial trauma in a traffic accident. CT scan of his left orbit showed a greatly increased orbital volume, which was resulted from the incomplete reduction of left zygomaticomaxillary complex (ZMC) fracture, unrepaired medial and lateral walls, and improper restoration of the orbital floor with a silicone sheet. Also, the decreased ocular volume, due to the evisceration of the ruptured eyeball with intraocular silicone ball implantation, contributed to the patient's enophthalmos. Because the patient refused any kind of osteotomy for his incompletely reduced and malunion ZMC fracture in the procedures of orbital reconstruction, correction of his severe enophthalmos became very difficult if not impossible. Therefore, we used a piece of titanium mesh plate about 2.5 x 4 cm in size, and folded it into an L shape. The shorter part of the L-shaped plate was used to fix the whole plate by screwing it into the anterior surface of the inferior orbital rim. The longer part of the plate was used as a new orbital floor. To hold and push the intraocular implant upward and anteriorly, the longer part of the plate was adjusted to a level higher than the original floor level, and was bent upward gently in the posterior part. Postoperatively, the severe enophthalmos was markedly improved, and the patient was satisfied although an evident supratarsal sulcus was still present. After a follow-up of 18 months, no complication of migration, infection, or extrusion of the titanium mesh plate occurred.
一位30岁的男性来我们这里矫正他严重的左眼内陷,五个月前他在一次交通事故中面部受伤。左眼眶CT扫描显示,由于左颧腋复合体(ZMC)骨折复位不全,内侧壁未修复,眶底硅胶片修复不当,导致眼眶体积大幅增加。此外,眼内硅胶球植入术切除破裂眼球,导致眼球体积减小,导致患者眼球内陷。由于患者在眶重建术中因ZMC骨折未完全复位和不愈合而拒绝任何形式的截骨,因此矫正其严重的眼内陷变得非常困难,如果不是不可能的话。因此,我们使用了一块尺寸约为2.5 x 4cm的钛网板,并将其折叠成L形。将l型钢板较短的部分旋入下眶缘前表面,固定整个钢板。板的较长部分被用作新的轨道底板。将钢板较长的部分调整到高于原底水位线的水平,并在后部轻轻向上弯曲,使眼内植入物向上向前固定和推动。术后严重眼内陷明显改善,患者满意,但仍有明显的跖骨上沟存在。随访18个月后,未发生钛网板移位、感染或挤压等并发症。