Characteristics of Nonylphenol and Octylphenol Discharge from Wastewater Treatment Facilities in Southern Gyeonggi-do

Soo-jung Seo, Phil-Kwon Choi, Wo-kyung Nam, Seon-Min Hwang, Jin-Young Lee, Seon-Hee Jung, Seogyeong Park
{"title":"Characteristics of Nonylphenol and Octylphenol Discharge from Wastewater Treatment Facilities in Southern Gyeonggi-do","authors":"Soo-jung Seo, Phil-Kwon Choi, Wo-kyung Nam, Seon-Min Hwang, Jin-Young Lee, Seon-Hee Jung, Seogyeong Park","doi":"10.36278/jeaht.26.2.67","DOIUrl":null,"url":null,"abstract":"This study aimed to evaluate the discharge characteristics of nonylphenol (NP) and octylphenol (OP) in the effluent of wastewater treatment facilities in the southern Gyeonggi-do. The detection rates of NP and OP were found to be 39.3% and 43.1%, respectively, with median values ranging from 1 to 3 μg/L across all industries. The industries that showed a detection rate of 50% or more were car wash, chemical experiment, fabric leather, paper wood, and plating facilities, with rates ranging from 50% to 75%, while other industries had detection rates of 21.7% to 36.8%. In terms of facility size, small-size establishments such as Type 4 and Type 5 showed higher detection rates in the \"Na\" region where somewhat relaxed standards are applied on a regional basis. This is because the proportion of Type 4 and Type 5 industries, including various concentration distributions of chemical experiments, research facilities, car washes, petrochemical, and plating industries, is higher than 77.7% overall and concentrated at a rate of 55.6% or higher in the “Na” region. Furthermore, the correlation coefficient (R) between NP and OP exhibited moderate association with values of 0.45 and 0.60 for car washes and plating industries, respectively. Chemical experiments, paper and wood, electrical and electronic, and medicine and hospital facilities showed strong association with correlation coefficients of 0.83, 0.82, 0.82, and 0.79, respectively. The findings in this study can be expected to serve as fundamental data for NP and OP in the establishment of water quality pollutants designation and discharge standards (draft) currently being pursued.","PeriodicalId":15758,"journal":{"name":"Journal of Environmental Analysis, Health and Toxicology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Environmental Analysis, Health and Toxicology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.36278/jeaht.26.2.67","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This study aimed to evaluate the discharge characteristics of nonylphenol (NP) and octylphenol (OP) in the effluent of wastewater treatment facilities in the southern Gyeonggi-do. The detection rates of NP and OP were found to be 39.3% and 43.1%, respectively, with median values ranging from 1 to 3 μg/L across all industries. The industries that showed a detection rate of 50% or more were car wash, chemical experiment, fabric leather, paper wood, and plating facilities, with rates ranging from 50% to 75%, while other industries had detection rates of 21.7% to 36.8%. In terms of facility size, small-size establishments such as Type 4 and Type 5 showed higher detection rates in the "Na" region where somewhat relaxed standards are applied on a regional basis. This is because the proportion of Type 4 and Type 5 industries, including various concentration distributions of chemical experiments, research facilities, car washes, petrochemical, and plating industries, is higher than 77.7% overall and concentrated at a rate of 55.6% or higher in the “Na” region. Furthermore, the correlation coefficient (R) between NP and OP exhibited moderate association with values of 0.45 and 0.60 for car washes and plating industries, respectively. Chemical experiments, paper and wood, electrical and electronic, and medicine and hospital facilities showed strong association with correlation coefficients of 0.83, 0.82, 0.82, and 0.79, respectively. The findings in this study can be expected to serve as fundamental data for NP and OP in the establishment of water quality pollutants designation and discharge standards (draft) currently being pursued.
京畿道南部污水处理设施壬基酚和辛基酚排放特征
本研究旨在评价京畿道南部污水处理设施出水中壬基酚(NP)和辛基酚(OP)的排放特性。NP和OP的检出率分别为39.3%和43.1%,各行业的中位数为1 ~ 3 μg/L。检出率在50%以上的行业是洗车、化学实验、织物皮革、纸木、电镀等行业,检出率在50% - 75%之间,其他行业的检出率为21.7% - 36.8%。在设施规模方面,在“Na”地区,4类和5类等小型设施的检出率较高,而“Na”地区的标准在区域基础上有所放宽。这是因为包括化学实验、研究设施、洗车、石油化工、电镀等行业的各种浓度分布在内的4类和5类行业占比总体高于77.7%,在“Na”地区的集中率达到55.6%或更高。此外,NP与OP之间的相关系数(R)呈中等相关性,洗车行业和电镀行业的相关系数分别为0.45和0.60。化学实验、纸张和木材、电气和电子、医药和医院设施的相关系数分别为0.83、0.82、0.82和0.79。本研究结果有望为国家和国家目前正在进行的水质污染物指定和排放标准(草案)的制定提供基础数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信