Colloidal matter separation of industrial wastewaters from Galați City area by semipermeable membranes

IF 1 Q4 CHEMISTRY, MULTIDISCIPLINARY
A. Tǎbǎcaru, S. Butan, R. Crețu
{"title":"Colloidal matter separation of industrial wastewaters from Galați City area by semipermeable membranes","authors":"A. Tǎbǎcaru, S. Butan, R. Crețu","doi":"10.2478/auoc-2022-0008","DOIUrl":null,"url":null,"abstract":"Abstract Various studies have shown that ultrafiltration membranes are successfully involved in the removal process of most organic pollutants from wastewater. In this context, the hydrodynamic characteristics of a modified cellulose ultrafiltration membrane were evaluated. This composite membrane type has been proposed for the separation of colloidal matter from industrial wastewater in Galati City area (Romania). Another purpose of this paper was also to determine the volume flows, along with the permeate and concentrate fluxes through the technical membrane taken under study. Furthermore, a comparative analysis of three samples of industrial water from Galați City area in terms of the degree of contamination was performed. Surface modification was evaluated using scanning electron microscopy. Results indicated that the industrial wastewater from the steel factory Liberty Galati was significantly more impure than the water from Cătuşa Lake, which in turn was more impure than the water from Siret River, as indicated by comparative analysis of the water samples subjected to the ultrafiltration operation through semipermeable technical membranes. It was shown that the decrease of the permeate flux at the modified cellulosic membrane was accentuated in the first moments, probably due to the clogging of the surface pores that present an uneven distribution. The results of the present study show that the cellulosic membrane used has pore diameters which correspond to the values recommended for the retention of colloidal matter.","PeriodicalId":19641,"journal":{"name":"Ovidius University Annals of Chemistry","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ovidius University Annals of Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/auoc-2022-0008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Various studies have shown that ultrafiltration membranes are successfully involved in the removal process of most organic pollutants from wastewater. In this context, the hydrodynamic characteristics of a modified cellulose ultrafiltration membrane were evaluated. This composite membrane type has been proposed for the separation of colloidal matter from industrial wastewater in Galati City area (Romania). Another purpose of this paper was also to determine the volume flows, along with the permeate and concentrate fluxes through the technical membrane taken under study. Furthermore, a comparative analysis of three samples of industrial water from Galați City area in terms of the degree of contamination was performed. Surface modification was evaluated using scanning electron microscopy. Results indicated that the industrial wastewater from the steel factory Liberty Galati was significantly more impure than the water from Cătuşa Lake, which in turn was more impure than the water from Siret River, as indicated by comparative analysis of the water samples subjected to the ultrafiltration operation through semipermeable technical membranes. It was shown that the decrease of the permeate flux at the modified cellulosic membrane was accentuated in the first moments, probably due to the clogging of the surface pores that present an uneven distribution. The results of the present study show that the cellulosic membrane used has pore diameters which correspond to the values recommended for the retention of colloidal matter.
用半透膜分离Galați市区工业废水中的胶体物质
各种研究表明,超滤膜成功地参与了废水中大多数有机污染物的去除过程。在此背景下,对改性纤维素超滤膜的水动力特性进行了评价。该复合膜类型已被提出用于罗马尼亚加拉提市地区工业废水中胶体物质的分离。本文的另一个目的是确定所研究的技术膜的体积流量以及渗透通量和浓缩通量。此外,还对Galați城市地区的三个工业用水样本进行了污染程度的比较分析。用扫描电镜对表面改性进行了评价。结果表明,经半透技术膜超滤处理的水样对比分析表明,Liberty Galati钢铁厂的工业废水明显高于ccurtu湖的水,而后者又高于Siret河的水。结果表明,改性纤维素膜上渗透通量的下降在初始时刻加剧,这可能是由于表面孔隙的堵塞造成的,表面孔隙分布不均匀。本研究的结果表明,所使用的纤维素膜的孔径与胶体物质保留的推荐值相对应。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Ovidius University Annals of Chemistry
Ovidius University Annals of Chemistry CHEMISTRY, MULTIDISCIPLINARY-
自引率
11.10%
发文量
20
审稿时长
5 weeks
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信