Ensuring Effective Functioning of Gas-Discharge Counters, Used in the Military Dose Rate Meters, in the Arctic Zone

{"title":"Ensuring Effective Functioning of Gas-Discharge Counters, Used in the Military Dose Rate Meters, in the Arctic Zone","authors":"","doi":"10.35825/2587-5728-2020-4-3-374-383","DOIUrl":null,"url":null,"abstract":"The Arctic zone is a priority area for the development and for ensuring the national security of the Russian Federation. At the same time, the region's rich natural resources create conditions for military conflicts and armed struggle of states for possession of these resources. Such conflicts might culminate with an exchange of nuclear strikes. The modern system of metrological support of military dosimetry equipment does not provide the necessary reliability of the verification and calibration procedure under low temperatures in the Arctic zone. The aim of this work is to ensure the effective functioning of gas-discharge counters, used in the military dose rate meters, in the Arctic Zone. It is established, that the reason for the low reliability of readings of military dosimeters can be the generation of false pulses due to a decrease in the suppressing ability of the counter. False impulses may appear soon after the completion of the verification. It is shown in the article, that in order to increase the reliability of measurements for devices on gas-discharge counters, it is necessary to introduce a diagnostic unit into their measuring circuit, which makes it possible to detect the presence of false pulses directly during the measurement. The implementation of the results obtained will increase the reliability of dosimetry equipment in the Far North and will also ensure greater safety of its metrological characteristics. In future, there are good reasons to conduct a study on transfer of dosimetry equipment to electronic control of gas-discharge counters in order to assess the\nincrease in the durability of the counters and reduce the cost of their production","PeriodicalId":16578,"journal":{"name":"Journal of NBC Protection Corps","volume":"32 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of NBC Protection Corps","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35825/2587-5728-2020-4-3-374-383","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The Arctic zone is a priority area for the development and for ensuring the national security of the Russian Federation. At the same time, the region's rich natural resources create conditions for military conflicts and armed struggle of states for possession of these resources. Such conflicts might culminate with an exchange of nuclear strikes. The modern system of metrological support of military dosimetry equipment does not provide the necessary reliability of the verification and calibration procedure under low temperatures in the Arctic zone. The aim of this work is to ensure the effective functioning of gas-discharge counters, used in the military dose rate meters, in the Arctic Zone. It is established, that the reason for the low reliability of readings of military dosimeters can be the generation of false pulses due to a decrease in the suppressing ability of the counter. False impulses may appear soon after the completion of the verification. It is shown in the article, that in order to increase the reliability of measurements for devices on gas-discharge counters, it is necessary to introduce a diagnostic unit into their measuring circuit, which makes it possible to detect the presence of false pulses directly during the measurement. The implementation of the results obtained will increase the reliability of dosimetry equipment in the Far North and will also ensure greater safety of its metrological characteristics. In future, there are good reasons to conduct a study on transfer of dosimetry equipment to electronic control of gas-discharge counters in order to assess the increase in the durability of the counters and reduce the cost of their production
确保北极地区军用剂量率计中气体放电计数器的有效运行
北极地区是俄罗斯联邦发展和确保国家安全的优先地区。同时,该地区丰富的自然资源也为各国争夺这些资源的军事冲突和武装斗争创造了条件。这种冲突可能会以相互的核打击而达到高潮。军事剂量测量设备的现代计量支持系统不能为北极地区低温下的验证和校准程序提供必要的可靠性。这项工作的目的是确保北极地区军用剂量率计中使用的气体放电计数器的有效运作。本文认为,军用剂量计读数可靠性低的原因可能是由于计数器抑制能力下降而产生假脉冲。在验证完成后不久可能会出现错误脉冲。本文指出,为了提高气体放电计数器上设备测量的可靠性,有必要在其测量电路中引入诊断单元,从而可以在测量过程中直接检测假脉冲的存在。所获得的结果的实施将提高远北地区剂量测定设备的可靠性,并将确保其计量特性的更大安全性。未来,有充分的理由进行剂量学设备转移到电子控制气体放电计数器的研究,以评估计数器耐久性的增加并降低其生产成本
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信