Sodium Chloride Concentration Measurement by Using Doping/Un-doping Poly-silicon Nanowire Device

Chang-Yuan Chen, Cheng-Chih Hsu, Chyan-Chyi Wu, C. Dai
{"title":"Sodium Chloride Concentration Measurement by Using Doping/Un-doping Poly-silicon Nanowire Device","authors":"Chang-Yuan Chen, Cheng-Chih Hsu, Chyan-Chyi Wu, C. Dai","doi":"10.17706/ijmse.2018.6.1.18-22","DOIUrl":null,"url":null,"abstract":"This work fabricates doping/un-doping poly-Si nanowire sensor with various lengths by using top-down technique for measuring salt concentration. Experimental results indicate that the resolution is proportional to the nanowire length and dopant concentration. But the sensitivity is inversely proportional to the length nanowire length. Moreover, the proposed sensor demonstrates 10 applications with similar current-time response and shows good repeatability.","PeriodicalId":16171,"journal":{"name":"Journal of materials science & engineering","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of materials science & engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17706/ijmse.2018.6.1.18-22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This work fabricates doping/un-doping poly-Si nanowire sensor with various lengths by using top-down technique for measuring salt concentration. Experimental results indicate that the resolution is proportional to the nanowire length and dopant concentration. But the sensitivity is inversely proportional to the length nanowire length. Moreover, the proposed sensor demonstrates 10 applications with similar current-time response and shows good repeatability.
用掺杂/未掺杂多晶硅纳米线器件测量氯化钠浓度
本工作采用自顶向下技术制备了不同长度掺杂/未掺杂多晶硅纳米线传感器,用于测量盐浓度。实验结果表明,分辨率与纳米线长度和掺杂剂浓度成正比。但灵敏度与纳米线长度成反比。此外,所提出的传感器在10个应用中具有相似的电流时间响应,并且具有良好的可重复性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信