Optimal Planning of Electric Vehicle Charging Station along with Multiple Distributed Generator Units

Q3 Computer Science
Devisree Chippada, M. D. Reddy
{"title":"Optimal Planning of Electric Vehicle Charging Station along with Multiple Distributed Generator Units","authors":"Devisree Chippada, M. D. Reddy","doi":"10.5815/ijisa.2022.02.04","DOIUrl":null,"url":null,"abstract":"Saving energy through the minimization of power losses in a distribution system is a key activity for efficient operation. Distributed Generation (DG) is one of the most efficient approaches to minimize losses. With increase in installation of Electric Vehicle Charging Stations (EVCSs) for Electrical Vehicles (EVs) in larger scale, optimal planning of EVCSs becomes a major challenge for distribution system operator. With increased EV load penetration in the electricity system, generation-demand mismatch and power losses increases. This results in poor voltage level, and deterioration in voltage stability margin. To mitigate the adverse impacts of increasing EV load penetration on Radial Distribution Systems (RDS), it is essential to integrate EVCSs at appropriate locations. The EVs integration into smart distribution systems involves Grid-to-Vehicle (G2V) and Vehicle-to-Grid (V2G) in charging and discharging modes of operation respectively for exchange of power with the grid thus resulting in energy management. The inappropriate planning of EVCSs causes a negative impact on the distribution system such as voltage deviation and an increase in power losses. In order to minimize this, DG units are integrated with EVCSs. The DGs assist in keeping the voltage profile within limitations, resulting in reduced power flows and losses, thereby enhancing power quality and reliability. Therefore, the DGs should be optimally allocated and sized along with the EVCS to avoid problems such as protection, voltage rise, and reverse power flow problems. This paper showcases a method to minimize losses using optimal location and sizing of multiple DGs and EVCS operating in G2V and V2G modes. The sizing and location of different types of DG units including renewables and non-renewables along with EV charging station is proposed in this study. This methodology overall reduces the power losses and also improves voltages of the network. The implementation is done by using the Simultaneous Particle Swarm Optimization technique (PSO) for IEEE 15, 33, 69 and 85 bus systems. The results indicate that the proposed optimization technique improves efficiency and performance of the system by optimal planning and operation of both DGs and EVs.","PeriodicalId":14067,"journal":{"name":"International Journal of Intelligent Systems and Applications in Engineering","volume":"337 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-04-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Intelligent Systems and Applications in Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5815/ijisa.2022.02.04","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Computer Science","Score":null,"Total":0}
引用次数: 7

Abstract

Saving energy through the minimization of power losses in a distribution system is a key activity for efficient operation. Distributed Generation (DG) is one of the most efficient approaches to minimize losses. With increase in installation of Electric Vehicle Charging Stations (EVCSs) for Electrical Vehicles (EVs) in larger scale, optimal planning of EVCSs becomes a major challenge for distribution system operator. With increased EV load penetration in the electricity system, generation-demand mismatch and power losses increases. This results in poor voltage level, and deterioration in voltage stability margin. To mitigate the adverse impacts of increasing EV load penetration on Radial Distribution Systems (RDS), it is essential to integrate EVCSs at appropriate locations. The EVs integration into smart distribution systems involves Grid-to-Vehicle (G2V) and Vehicle-to-Grid (V2G) in charging and discharging modes of operation respectively for exchange of power with the grid thus resulting in energy management. The inappropriate planning of EVCSs causes a negative impact on the distribution system such as voltage deviation and an increase in power losses. In order to minimize this, DG units are integrated with EVCSs. The DGs assist in keeping the voltage profile within limitations, resulting in reduced power flows and losses, thereby enhancing power quality and reliability. Therefore, the DGs should be optimally allocated and sized along with the EVCS to avoid problems such as protection, voltage rise, and reverse power flow problems. This paper showcases a method to minimize losses using optimal location and sizing of multiple DGs and EVCS operating in G2V and V2G modes. The sizing and location of different types of DG units including renewables and non-renewables along with EV charging station is proposed in this study. This methodology overall reduces the power losses and also improves voltages of the network. The implementation is done by using the Simultaneous Particle Swarm Optimization technique (PSO) for IEEE 15, 33, 69 and 85 bus systems. The results indicate that the proposed optimization technique improves efficiency and performance of the system by optimal planning and operation of both DGs and EVs.
带多个分布式发电机组的电动汽车充电站优化规划
在配电系统中,通过最小化功率损耗来节约能源是高效运行的关键活动。分布式发电(DG)是减少损失的最有效方法之一。随着电动汽车充电站的大规模安装,充电站的优化规划成为配电系统运营商面临的主要挑战。随着电动汽车负荷在电力系统中的渗透增加,发电需求失配和电力损耗也随之增加。这导致电压水平差,电压稳定裕度恶化。为了减轻电动汽车负荷渗透增加对径向配电系统(RDS)的不利影响,必须在适当的位置集成电动汽车。电动汽车与智能配电系统的集成涉及电网对车辆(G2V)和车辆对电网(V2G)的充电和放电操作模式,以与电网交换电力,从而实现能源管理。evcs规划不当,会对配电系统造成电压偏差、网损增加等负面影响。为了尽量减少这种情况,DG单元与evcs集成在一起。dg有助于将电压分布保持在限制范围内,从而减少功率流和损耗,从而提高电源质量和可靠性。因此,dg应与EVCS一起优化分配和大小,以避免出现保护、电压上升和反向潮流等问题。本文展示了一种在G2V和V2G模式下使用多个dg和EVCS的最佳位置和尺寸来最小化损失的方法。本文提出了不同类型的可再生能源和非可再生能源发电机组以及电动汽车充电站的规模和位置。这种方法总体上减少了功率损耗,也提高了网络的电压。采用同步粒子群优化技术(PSO)实现了ieee15、33,69和85总线系统。结果表明,该优化技术通过对电动汽车和电动汽车的优化规划和运行,提高了系统的效率和性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
International Journal of Intelligent Systems and Applications in Engineering
International Journal of Intelligent Systems and Applications in Engineering Computer Science-Computer Graphics and Computer-Aided Design
CiteScore
1.30
自引率
0.00%
发文量
18
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信