Fluorescence determination of acrylamide in potato chips based on P540 and P503 fluorescent reagents

IF 1 4区 工程技术 Q4 CHEMISTRY, MULTIDISCIPLINARY
Leila Baharinikoo, M. Chaichi, M. Ganjali
{"title":"Fluorescence determination of acrylamide in potato chips based on P540 and P503 fluorescent reagents","authors":"Leila Baharinikoo, M. Chaichi, M. Ganjali","doi":"10.30492/IJCCE.2021.109173.3622","DOIUrl":null,"url":null,"abstract":"Acrylamide is one of the potential environmental public health problems, resulting from its increased accumulation in the process of cooking foods content high level of carbohydrates that are fried or cooked at high temperatures. So, developing a precise and sensitive analytical method for detecting and determining acrylamide in foods is absolutely necessary and inevitable. Gas chromatography (GC) and liquid chromatography (LC) are two main laboratory techniques for acrylamide determination. In this study, we tried to use a cheaper, faster, accurately method for measuring acrylamide in real food samples. P540 and P503 were used as fluorescent reagent to detect the concentration of acrylamide in potato chips samples from 4 companies. Fluorescence spectroscopy was used in this work. The results obtained for the detection of acrylamide in comparison with the HPLC-MS method showed that there is an acceptable overlap between the fluorescence spectroscopy and HPLC method. The amount of acrylamide in four potato chips samples, obtained from the market in Tehran city, was determined using the proposed method. The optimum values of different parameters, were determined. Comparison between two methods, HPLC-MS and fluorescence spectroscopy were also described. The figures of merit for the proposed method were at the ideal range. The developed methods showed a high correlation coefficient (R2= 0.991). According to the results of the fluorescence emission spectroscopy and its comparison with HPLC-MS, performance and reliability of proposed method as a simple, efficient and rapid method with reduction of cost and time for determining acrylamide in potato chip samples were demonstrated.","PeriodicalId":14572,"journal":{"name":"Iranian Journal of Chemistry & Chemical Engineering-international English Edition","volume":"67 1","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2021-11-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Chemistry & Chemical Engineering-international English Edition","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.30492/IJCCE.2021.109173.3622","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Acrylamide is one of the potential environmental public health problems, resulting from its increased accumulation in the process of cooking foods content high level of carbohydrates that are fried or cooked at high temperatures. So, developing a precise and sensitive analytical method for detecting and determining acrylamide in foods is absolutely necessary and inevitable. Gas chromatography (GC) and liquid chromatography (LC) are two main laboratory techniques for acrylamide determination. In this study, we tried to use a cheaper, faster, accurately method for measuring acrylamide in real food samples. P540 and P503 were used as fluorescent reagent to detect the concentration of acrylamide in potato chips samples from 4 companies. Fluorescence spectroscopy was used in this work. The results obtained for the detection of acrylamide in comparison with the HPLC-MS method showed that there is an acceptable overlap between the fluorescence spectroscopy and HPLC method. The amount of acrylamide in four potato chips samples, obtained from the market in Tehran city, was determined using the proposed method. The optimum values of different parameters, were determined. Comparison between two methods, HPLC-MS and fluorescence spectroscopy were also described. The figures of merit for the proposed method were at the ideal range. The developed methods showed a high correlation coefficient (R2= 0.991). According to the results of the fluorescence emission spectroscopy and its comparison with HPLC-MS, performance and reliability of proposed method as a simple, efficient and rapid method with reduction of cost and time for determining acrylamide in potato chip samples were demonstrated.
基于P540和P503荧光试剂的薯片中丙烯酰胺的荧光测定
丙烯酰胺是潜在的环境公共卫生问题之一,由于其在烹饪过程中积累增加,在油炸或高温烹饪的食物中含有高水平的碳水化合物。因此,开发一种准确、灵敏的食品中丙烯酰胺的检测方法是十分必要和必然的。气相色谱(GC)和液相色谱(LC)是测定丙烯酰胺的两种主要实验室技术。在这项研究中,我们试图使用一种更便宜、更快、更准确的方法来测量真实食品样品中的丙烯酰胺。采用P540和P503作为荧光试剂检测4家公司薯片样品中丙烯酰胺的浓度。荧光光谱技术被用于这项工作。将丙烯酰胺的检测结果与高效液相色谱-质谱法进行比较,结果表明荧光光谱法与高效液相色谱法有可接受的重叠。采用上述方法测定了从德黑兰市市场获得的四个薯片样品中的丙烯酰胺含量。确定了不同工艺参数的最优值。并对HPLC-MS和荧光光谱两种方法进行了比较。所提出的方法的优点数字处于理想范围。所建方法的相关系数较高(R2= 0.991)。根据荧光发射光谱分析结果及其与高效液相色谱-质谱分析的对比,证明了该方法的性能和可靠性,是一种简便、高效、快速的薯片样品丙烯酰胺测定方法,降低了成本和时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.80
自引率
22.20%
发文量
0
审稿时长
6-12 weeks
期刊介绍: The aim of the Iranian Journal of Chemistry and Chemical Engineering is to foster the growth of educational, scientific and Industrial Research activities among chemists and chemical engineers and to provide a medium for mutual communication and relations between Iranian academia and the industry on the one hand, and the world the scientific community on the other.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信