Shunzhou Chu, F. Bai, Zhiying Cui, Fuliang Nie, Zhifeng Wang
{"title":"Experimental study of a heat pipe pressurized air receiver","authors":"Shunzhou Chu, F. Bai, Zhiying Cui, Fuliang Nie, Zhifeng Wang","doi":"10.1063/1.5117527","DOIUrl":null,"url":null,"abstract":"This study investigated the startup characteristics and thermal performance of a heat pipe pressurized air receiver. The heat flux on the receiver of around 130 kW/m2 was tested to be an appropriat...","PeriodicalId":21790,"journal":{"name":"SOLARPACES 2018: International Conference on Concentrating Solar Power and Chemical Energy Systems","volume":"73 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SOLARPACES 2018: International Conference on Concentrating Solar Power and Chemical Energy Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1063/1.5117527","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This study investigated the startup characteristics and thermal performance of a heat pipe pressurized air receiver. The heat flux on the receiver of around 130 kW/m2 was tested to be an appropriat...