Directly Filtering the Sparse-View CT Images by BM3D

G. Zeng
{"title":"Directly Filtering the Sparse-View CT Images by BM3D","authors":"G. Zeng","doi":"10.1117/12.2646426","DOIUrl":null,"url":null,"abstract":"The x-ray computed tomography (CT) images with sparse-view data acquisition contain severe angular aliasing artifacts. The common denoising filters do not work well. The state-of-the-art methods to process the sparse-view CT images are deep learning based; they require a large amount of training data pairs. This paper considers a situation where no training data sets are available. All we have is one sparse scan of a patient. This paper attempts to use a BM3D filter to reduce the artifacts by introducing an artifact power spectral density function, which is calculated with computer simulations. The results in this paper show that the proposed method is not effective enough for practice applications. However, some insights may lead us to further investigations.","PeriodicalId":74805,"journal":{"name":"SL clinical medicine : research","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SL clinical medicine : research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2646426","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The x-ray computed tomography (CT) images with sparse-view data acquisition contain severe angular aliasing artifacts. The common denoising filters do not work well. The state-of-the-art methods to process the sparse-view CT images are deep learning based; they require a large amount of training data pairs. This paper considers a situation where no training data sets are available. All we have is one sparse scan of a patient. This paper attempts to use a BM3D filter to reduce the artifacts by introducing an artifact power spectral density function, which is calculated with computer simulations. The results in this paper show that the proposed method is not effective enough for practice applications. However, some insights may lead us to further investigations.
BM3D直接过滤稀疏视图CT图像
稀疏视图数据采集的x射线计算机断层扫描(CT)图像存在严重的角混叠伪影。常用的去噪滤波器效果不佳。最先进的稀疏视图CT图像处理方法是基于深度学习的;它们需要大量的训练数据对。本文考虑了一种没有训练数据集的情况。我们只有一个病人的稀疏扫描。本文通过引入伪影功率谱密度函数,尝试利用BM3D滤波器来减少伪影,并通过计算机仿真计算。结果表明,该方法在实际应用中效果不理想。然而,一些见解可能会引导我们进行进一步的研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信