{"title":"HEAT TRANSFER IN A FLUIDIZED SOLIDS BED","authors":"J. Klassen, P. E. Gishler, A. Baerg","doi":"10.1139/CJR50F-025","DOIUrl":null,"url":null,"abstract":"Heat transfer coefficients have been determined in a fluidized solids bed under a wide variety of conditions. The variables studied were particle size, bulk density under nonfluidized conditions, particle shape, and air velocity. Simple correlations have been established predicting the value of h in the air flow range investigated. An equation predicting the minimum fluidizing velocity has also been derived.","PeriodicalId":9392,"journal":{"name":"Canadian journal of research","volume":"176 1","pages":"287-307"},"PeriodicalIF":0.0000,"publicationDate":"1950-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"19","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Canadian journal of research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1139/CJR50F-025","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 19
Abstract
Heat transfer coefficients have been determined in a fluidized solids bed under a wide variety of conditions. The variables studied were particle size, bulk density under nonfluidized conditions, particle shape, and air velocity. Simple correlations have been established predicting the value of h in the air flow range investigated. An equation predicting the minimum fluidizing velocity has also been derived.