ERT geoelectric application to determine the leakage direction of Embung Batur Agung, Karangwetan, Karangmojo District, Gunungkidul Regency, Indonesia

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY
M. Zakaria, S. Kusumayudha, H. Hamid
{"title":"ERT geoelectric application to determine the leakage direction of Embung Batur Agung, Karangwetan, Karangmojo District, Gunungkidul Regency, Indonesia","authors":"M. Zakaria, S. Kusumayudha, H. Hamid","doi":"10.11591/ijaas.v12.i2.pp93-102","DOIUrl":null,"url":null,"abstract":"Embung Batur Agung is a source of irrigation for residents around Embung. Depreciation of water in the reservoir occurs due to leakage from the geomembrane layer of the Embung Batur Agung. This study aims to determine the direction of leakage from the reservoir so that appropriate treatment can be carried out. This research was done using hydrogeological analysis and electrical resistivity tomography (ERT) geoelectrical measurements. ERT Geoelectrical measurement uses a dipole-dipole configuration with a spacing of 5 m and 10 m and a line length of 100 m. There are 2 lines in the southwest and southeast of the reservoir. The results of geohydrology analysis, it was found that the aquifer system around the reservoir included in the Gunungsewu aquifer system, and the dynamics of surface groundwater are controlled by faults and fractures. The results of the ERT geoelectrical measurement, there is a low anomaly which can indicate a reservoir leak at 50-60 m on line 1 which is in the southwest of the reservoir. This low anomaly has a vertical pattern as well as there is a fracture which is the cause of the reservoir leak. These low anomaly values range from 4-30 Ωm which can be interpreted as the presence of water that has conductive properties. The results of this study are expected to be used by the local government to handle the leakage of the reservoir.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11591/ijaas.v12.i2.pp93-102","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Embung Batur Agung is a source of irrigation for residents around Embung. Depreciation of water in the reservoir occurs due to leakage from the geomembrane layer of the Embung Batur Agung. This study aims to determine the direction of leakage from the reservoir so that appropriate treatment can be carried out. This research was done using hydrogeological analysis and electrical resistivity tomography (ERT) geoelectrical measurements. ERT Geoelectrical measurement uses a dipole-dipole configuration with a spacing of 5 m and 10 m and a line length of 100 m. There are 2 lines in the southwest and southeast of the reservoir. The results of geohydrology analysis, it was found that the aquifer system around the reservoir included in the Gunungsewu aquifer system, and the dynamics of surface groundwater are controlled by faults and fractures. The results of the ERT geoelectrical measurement, there is a low anomaly which can indicate a reservoir leak at 50-60 m on line 1 which is in the southwest of the reservoir. This low anomaly has a vertical pattern as well as there is a fracture which is the cause of the reservoir leak. These low anomaly values range from 4-30 Ωm which can be interpreted as the presence of water that has conductive properties. The results of this study are expected to be used by the local government to handle the leakage of the reservoir.
ERT地电应用于确定印度尼西亚Gunungkidul Regency Karangmojo区Karangwetan的Embung Batur Agung的泄漏方向
恩邦巴图尔阿贡是恩邦附近居民的灌溉水源。水库中水的贬值是由于Embung Batur Agung土工膜层渗漏造成的。本研究旨在确定储层渗漏的方向,以便进行适当的处理。本研究采用水文地质分析和电阻率层析成像(ERT)地电测量方法。ERT地电测量采用偶极-偶极配置,间距为5米和10米,线长为100米。水库西南、东南有2条线。地质水文分析结果表明,库区周围的含水层系统属于Gunungsewu含水层系统,地表地下水的动态受断层和裂缝控制。ERT地电测量结果显示,在水库西南1号线50 ~ 60 m处有一个低异常,表明有水库泄漏。该低异常呈垂向分布,且存在裂缝,是导致储层渗漏的原因。这些低异常值范围为4-30 Ωm,这可以解释为存在具有导电性的水。这项研究的结果有望被当地政府用于处理水库的泄漏。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信