DESIGN NOTE: Microprocessor-based 250-1100 nm photometer with flat spectral response

H. S. Vora, T. N. Das, V. Kumar, M. N. Kumbhare, R. Koul
{"title":"DESIGN NOTE: Microprocessor-based 250-1100 nm photometer with flat spectral response","authors":"H. S. Vora, T. N. Das, V. Kumar, M. N. Kumbhare, R. Koul","doi":"10.1088/0022-3735/22/10/015","DOIUrl":null,"url":null,"abstract":"The digital photometer system developed earlier has been upgraded by incorporating a microprocessor-based system with it. The optical response of the system is uniform in the detection range of 250-1100 nm. The associated non-linearity of measurements of high irradiance has also been removed by suitable circuit modifications. The system is now capable of storing time profiles of photometric data and has enhanced user-friendly options.","PeriodicalId":16791,"journal":{"name":"Journal of Physics E: Scientific Instruments","volume":"102 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"1989-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Physics E: Scientific Instruments","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/0022-3735/22/10/015","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

The digital photometer system developed earlier has been upgraded by incorporating a microprocessor-based system with it. The optical response of the system is uniform in the detection range of 250-1100 nm. The associated non-linearity of measurements of high irradiance has also been removed by suitable circuit modifications. The system is now capable of storing time profiles of photometric data and has enhanced user-friendly options.
设计说明:基于微处理器的250-1100 nm光度计,具有平坦的光谱响应
早先开发的数字光度计系统已经升级,加入了一个基于微处理器的系统。在250 ~ 1100nm的探测范围内,系统的光响应均匀。通过适当的电路修改,也消除了高辐照度测量的相关非线性。该系统现在能够存储光度数据的时间概况,并具有增强的用户友好选项。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信