{"title":"High-Bandwidth Shielded Rogowski Coil Current Sensor for SiC MOSFET Power Module","authors":"Wen Zhang, Fred Wang, B. Holzinger","doi":"10.1109/APEC42165.2021.9487370","DOIUrl":null,"url":null,"abstract":"Existing current sensors suffer from insufficient measurement bandwidth or large insertion area to continuously monitor the switching transient current of wide-bandgap devices. A combinational Rogowski coil concept is proposed here, where the self-integrating region of a shielded Rogowski coil is combined with its differentiating region. The overall measurement bandwidth is effectively extended by the self-integrating region. The design methodology for the shielded Rogowski coil, especially the parasitic elements and error analysis, is discussed. Finally, a prototype is demonstrated with a sensitivity is 5.0 mΩ and a bandwidth of 200 MHz. The measurement in a SiC power module double pulse shows it can faithfully capture the transient current while introducing little interference.","PeriodicalId":7050,"journal":{"name":"2021 IEEE Applied Power Electronics Conference and Exposition (APEC)","volume":"35 1","pages":"1242-1249"},"PeriodicalIF":0.0000,"publicationDate":"2021-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE Applied Power Electronics Conference and Exposition (APEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEC42165.2021.9487370","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
Existing current sensors suffer from insufficient measurement bandwidth or large insertion area to continuously monitor the switching transient current of wide-bandgap devices. A combinational Rogowski coil concept is proposed here, where the self-integrating region of a shielded Rogowski coil is combined with its differentiating region. The overall measurement bandwidth is effectively extended by the self-integrating region. The design methodology for the shielded Rogowski coil, especially the parasitic elements and error analysis, is discussed. Finally, a prototype is demonstrated with a sensitivity is 5.0 mΩ and a bandwidth of 200 MHz. The measurement in a SiC power module double pulse shows it can faithfully capture the transient current while introducing little interference.