Effect of Sunlight, Moisture, Temperature and Ultraviolet Radiation on the Quality Control Parameters of Ciprofloxacin Tablet Formulation

K. M. Ezealisiji, Angenlina Pepple, C. Stanley
{"title":"Effect of Sunlight, Moisture, Temperature and Ultraviolet Radiation on the Quality Control Parameters of Ciprofloxacin Tablet Formulation","authors":"K. M. Ezealisiji, Angenlina Pepple, C. Stanley","doi":"10.5138/09750215.1928","DOIUrl":null,"url":null,"abstract":"This work assesses the stability and quality of Ciprofloxacin hydrochloride tablets after subjection to accelerated stability conditions of sunlight, temperature of 40±1 0 C, 75% relative humidity, and UV light of 365 nm for 4 hours each day. This study was performed at time zero and at 4-day intervals for a period of 45 days (that is, days 0, 4, 8, 12…40, 44) according to the International Conference on Harmonization (ICH) accelerated aging conditions and the results obtained were subjected to statistical analysis. The results showed that with increasing time there was a gradual reduction in the dissolution rate with the tablets exposed to all four storage conditions failing the test on day 44 where they had less than 80 % release of the label claim. For content of Ciprofloxacin Hydrochloride, only those tablets exposed to UV light passed the test for all 44 days as they had a minimum of 96.83 % content on the 44 th day. At day 0, all the tablets assayed passed this test, having a ciprofloxacin content of 99.43 %. For those tablets subjected to the other storage conditions including temperature of 40±1 0 C, 75 % relative humidity and sunlight, they had ciprofloxacin content of 70.22 %, 71.50 %, and 78.36 % respectively. The results further, indicated that the storage conditions used in the study had a greater impact on the dissolution behavior and content of the Ciprofloxacin tablets than they did on the physical stability (hardness, uniformity of weight, disintegration).","PeriodicalId":13912,"journal":{"name":"International Journal of Drug Delivery","volume":"106 1","pages":"99-106"},"PeriodicalIF":0.0000,"publicationDate":"2016-12-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Drug Delivery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5138/09750215.1928","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

This work assesses the stability and quality of Ciprofloxacin hydrochloride tablets after subjection to accelerated stability conditions of sunlight, temperature of 40±1 0 C, 75% relative humidity, and UV light of 365 nm for 4 hours each day. This study was performed at time zero and at 4-day intervals for a period of 45 days (that is, days 0, 4, 8, 12…40, 44) according to the International Conference on Harmonization (ICH) accelerated aging conditions and the results obtained were subjected to statistical analysis. The results showed that with increasing time there was a gradual reduction in the dissolution rate with the tablets exposed to all four storage conditions failing the test on day 44 where they had less than 80 % release of the label claim. For content of Ciprofloxacin Hydrochloride, only those tablets exposed to UV light passed the test for all 44 days as they had a minimum of 96.83 % content on the 44 th day. At day 0, all the tablets assayed passed this test, having a ciprofloxacin content of 99.43 %. For those tablets subjected to the other storage conditions including temperature of 40±1 0 C, 75 % relative humidity and sunlight, they had ciprofloxacin content of 70.22 %, 71.50 %, and 78.36 % respectively. The results further, indicated that the storage conditions used in the study had a greater impact on the dissolution behavior and content of the Ciprofloxacin tablets than they did on the physical stability (hardness, uniformity of weight, disintegration).
光照、湿度、温度和紫外线辐射对环丙沙星片制剂质量控制参数的影响
本研究对盐酸环丙沙星片在光照、温度40±10℃、相对湿度75%、365 nm紫外光每天照射4小时的加速稳定条件下的稳定性和质量进行了评价。根据国际协调会议(ICH)的加速老化条件,本研究在时间0和间隔4天进行,为期45天(即0、4、8、12、40、44天),所得结果进行统计分析。结果表明,随着时间的增加,溶出率逐渐降低,暴露于所有四种储存条件下的片剂在第44天未能通过测试,因为它们的标签声明释放量低于80%。对于盐酸环丙沙星含量,只有在紫外光照射下44天均通过检测,第44天含量最低为96.83%。第0天,所有样品均通过本试验,环丙沙星含量为99.43%。在温度为40±10℃、相对湿度为75%、光照条件下,环丙沙星含量分别为70.22%、71.50%、78.36%。研究结果进一步表明,贮藏条件对环丙沙星片的溶出行为和含量的影响大于对其物理稳定性(硬度、重量均匀性、崩解性)的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信