Development of Recombinant Immunoblot Assay Diagnostic Test Based on HIV-1 in Indonesia

J. Christian, S. T. Widyaningtyas, B. Bela
{"title":"Development of Recombinant Immunoblot Assay Diagnostic Test Based on HIV-1 in Indonesia","authors":"J. Christian, S. T. Widyaningtyas, B. Bela","doi":"10.21705/mcbs.v6i2.251","DOIUrl":null,"url":null,"abstract":"Background: High mutation rates in HIV-1 could affect the accuracy of diagnostic tests. Therefore, recombinant antigen that has an immunodominant and conserved region from HIV-1 need to be developed to detect HIV-1 infection in Indonesia.Materials and methods: The recombinant antigens comprise of Gag (p24), Pol and Env (gp41). Each antigens was expressed in the Escherichia coli expression system and purified using Ni-NTA chromatography. The reactivity of purified antigen against HIV antibodies was tested against a group of 50 HIV-positive plasma samples and 45 HIV-negative plasma samples in a recombinant immunoblot assay (RIBA) platform test. Moreover, 21 of 50 HIV-positive samples and 3 of 45 HIV-negative samples were also tested using HIV blot 2.2 to compare RIBA with a commercial western blot kit. Ten HBV-positive and 10 HCV-positive plasma samples were used to check cross-reactivity with HIV recombinant proteins in RIBA.Results: All HIV-positive samples (100%) tested with RIBA were reactive towards Gag (p24), Pol, Env (gp41). Otherwise, 3 of 21 HIV-positive samples assayed with HIV blot 2.2 were not reactive to Pol protein. All HIV-negative samples tested with RIBA and 3 HIV-negative samples tested with HIV blot 2.2 did not produce any bands of HIV antigens. Few HBV and HCV samples showed reactivity towards HIV recombinant proteins.Conclusion: Each recombinant protein, Gag (p24), Pol, Env (gp41), could be expressed and purified, as well as had reactivity to HIV-positive samples in RIBA test. Therefore, RIBA can be used as a diagnostic test to detect HIV-1 infection in Indonesia.Keywords: diagnostic, HIV-1, immunodominant, recombinant immunoblot assay (RIBA)","PeriodicalId":53387,"journal":{"name":"MCBS Molecular and Cellular Biomedical Sciences","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-07-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"MCBS Molecular and Cellular Biomedical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21705/mcbs.v6i2.251","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: High mutation rates in HIV-1 could affect the accuracy of diagnostic tests. Therefore, recombinant antigen that has an immunodominant and conserved region from HIV-1 need to be developed to detect HIV-1 infection in Indonesia.Materials and methods: The recombinant antigens comprise of Gag (p24), Pol and Env (gp41). Each antigens was expressed in the Escherichia coli expression system and purified using Ni-NTA chromatography. The reactivity of purified antigen against HIV antibodies was tested against a group of 50 HIV-positive plasma samples and 45 HIV-negative plasma samples in a recombinant immunoblot assay (RIBA) platform test. Moreover, 21 of 50 HIV-positive samples and 3 of 45 HIV-negative samples were also tested using HIV blot 2.2 to compare RIBA with a commercial western blot kit. Ten HBV-positive and 10 HCV-positive plasma samples were used to check cross-reactivity with HIV recombinant proteins in RIBA.Results: All HIV-positive samples (100%) tested with RIBA were reactive towards Gag (p24), Pol, Env (gp41). Otherwise, 3 of 21 HIV-positive samples assayed with HIV blot 2.2 were not reactive to Pol protein. All HIV-negative samples tested with RIBA and 3 HIV-negative samples tested with HIV blot 2.2 did not produce any bands of HIV antigens. Few HBV and HCV samples showed reactivity towards HIV recombinant proteins.Conclusion: Each recombinant protein, Gag (p24), Pol, Env (gp41), could be expressed and purified, as well as had reactivity to HIV-positive samples in RIBA test. Therefore, RIBA can be used as a diagnostic test to detect HIV-1 infection in Indonesia.Keywords: diagnostic, HIV-1, immunodominant, recombinant immunoblot assay (RIBA)
印度尼西亚HIV-1重组免疫印迹诊断试验的发展
背景:HIV-1的高突变率可能影响诊断测试的准确性。因此,需要开发具有HIV-1免疫优势和保守区域的重组抗原来检测印度尼西亚的HIV-1感染。材料和方法:重组抗原由Gag (p24)、Pol和Env (gp41)组成。每个抗原在大肠杆菌表达系统中表达,并使用Ni-NTA层析纯化。在重组免疫印迹(RIBA)平台试验中,对50份HIV阳性血浆样本和45份HIV阴性血浆样本检测纯化抗原对HIV抗体的反应性。此外,50个HIV阳性样本中的21个和45个HIV阴性样本中的3个也使用HIV blot 2.2进行检测,以将RIBA与商业western blot试剂盒进行比较。10例hbv阳性和10例hcv阳性血浆样本检测RIBA与HIV重组蛋白的交叉反应性。结果:所有hiv阳性样本(100%)对Gag (p24)、Pol、Env (gp41)均有反应。另外,21例HIV阳性样本中有3例对Pol蛋白无反应。用RIBA检测的所有HIV阴性样本和3个HIV blot 2.2检测的HIV阴性样本未产生任何HIV抗原条带。少数HBV和HCV样品对HIV重组蛋白表现出反应性。结论:Gag (p24)、Pol (gp41)、Env (gp41)等重组蛋白均可表达纯化,且在RIBA试验中对hiv阳性样品具有反应性。因此,RIBA可以作为印度尼西亚HIV-1感染的诊断测试。关键词:诊断,HIV-1,免疫优势,重组免疫印迹法(RIBA)
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
20 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信