Effect of liquid condition on moisture saturation coefficients in synthetic and natural esters

P. Livesey, A. Gyore, James Reid
{"title":"Effect of liquid condition on moisture saturation coefficients in synthetic and natural esters","authors":"P. Livesey, A. Gyore, James Reid","doi":"10.1109/ICD46958.2020.9341877","DOIUrl":null,"url":null,"abstract":"The liquid specific moisture saturation coefficients A and B are required for accurate use of thin film capacitance moisture sensors. These have been previously produced and evaluated for new liquids including synthetic and natural esters. In-use synthetic and natural esters have not yet been evaluated. This paper aims to demonstrate the difference in results of aged esters compared to new, as well as demonstrating the effect on results which can be caused by using improper methods in these liquids. The results highlight the importance of using liquids with high enough initial moisture content and also demonstrate that the moisture saturation curve is mostly unchanged by changing the temperatures used in calculation. The results also show that ageing the synthetic ester in different ways did not significantly affect the moisture saturation curve, however ageing the natural ester open to air led to an increase in measured saturation limit at all temperatures when it was heavily oxidised. It is hypothesised that this is due to the presence of oxidation products other than acid in the natural ester.","PeriodicalId":6795,"journal":{"name":"2020 IEEE 3rd International Conference on Dielectrics (ICD)","volume":"38 1","pages":"728-731"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE 3rd International Conference on Dielectrics (ICD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICD46958.2020.9341877","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The liquid specific moisture saturation coefficients A and B are required for accurate use of thin film capacitance moisture sensors. These have been previously produced and evaluated for new liquids including synthetic and natural esters. In-use synthetic and natural esters have not yet been evaluated. This paper aims to demonstrate the difference in results of aged esters compared to new, as well as demonstrating the effect on results which can be caused by using improper methods in these liquids. The results highlight the importance of using liquids with high enough initial moisture content and also demonstrate that the moisture saturation curve is mostly unchanged by changing the temperatures used in calculation. The results also show that ageing the synthetic ester in different ways did not significantly affect the moisture saturation curve, however ageing the natural ester open to air led to an increase in measured saturation limit at all temperatures when it was heavily oxidised. It is hypothesised that this is due to the presence of oxidation products other than acid in the natural ester.
液体条件对合成酯和天然酯中水分饱和系数的影响
液体比湿饱和系数A和B是精确使用薄膜电容式水分传感器所必需的。这些之前已经生产并评估了新的液体,包括合成和天然酯。目前尚未对使用中的合成酯和天然酯进行评价。本文旨在证明老化酯与新酯在结果上的差异,以及证明在这些液体中使用不当方法可能对结果造成的影响。结果表明,使用足够高的初始含水率的液体的重要性,也表明,在改变计算中使用的温度时,水分饱和度曲线基本不变。结果还表明,不同老化方式对合成酯的水分饱和度曲线没有显著影响,而天然酯在空气中老化导致在所有温度下,当它被严重氧化时,测量的饱和极限都增加。据推测,这是由于天然酯中存在除酸以外的氧化产物。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信