The Bifurcated Detection using the Sensing Coil for Parallel-Parallel Compensation in IPT System

Nattapong Hatchavanich, A. Sangswang, M. Konghirun
{"title":"The Bifurcated Detection using the Sensing Coil for Parallel-Parallel Compensation in IPT System","authors":"Nattapong Hatchavanich, A. Sangswang, M. Konghirun","doi":"10.1109/IECON43393.2020.9254747","DOIUrl":null,"url":null,"abstract":"The bifurcation phenomenon is the usually found in inductive power transfer system (IPT). The coupling and load on secondary side that induce the bifurcation cannot could not be directly measured. This paper presents the bifurcated detection by using the sensing coil. The sensing coil is placed on the secondary side. The phase of the sensing coil voltage is compared with the phase of secondary voltage to indicate the bifurcation. The frequency responses show that the phase difference between sensing coil voltage and secondary voltage is decreased when increased the secondary quality factor. The experimental results revealed that the bifurcation was detected from the secondary side in both perfect alignment and misalignment condition. By using the proposed circuit, the bifurcation detection from the secondary side is possible.","PeriodicalId":13045,"journal":{"name":"IECON 2020 The 46th Annual Conference of the IEEE Industrial Electronics Society","volume":"76 1","pages":"5268-5272"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IECON 2020 The 46th Annual Conference of the IEEE Industrial Electronics Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IECON43393.2020.9254747","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The bifurcation phenomenon is the usually found in inductive power transfer system (IPT). The coupling and load on secondary side that induce the bifurcation cannot could not be directly measured. This paper presents the bifurcated detection by using the sensing coil. The sensing coil is placed on the secondary side. The phase of the sensing coil voltage is compared with the phase of secondary voltage to indicate the bifurcation. The frequency responses show that the phase difference between sensing coil voltage and secondary voltage is decreased when increased the secondary quality factor. The experimental results revealed that the bifurcation was detected from the secondary side in both perfect alignment and misalignment condition. By using the proposed circuit, the bifurcation detection from the secondary side is possible.
IPT系统并联补偿中传感线圈的分岔检测
分岔现象是感应输电系统中常见的现象。引起分岔的二次侧耦合和载荷不能直接测量。本文介绍了利用传感线圈进行分岔检测的方法。感应线圈放置在二次侧。将感应线圈电压的相位与次级电压的相位进行比较,以指示分岔。频率响应结果表明,当二次质量因数增大时,感应线圈电压与二次电压之间的相位差减小。实验结果表明,在完全对准和不对准条件下,二次侧都能检测到分岔。利用所提出的电路,从二次侧进行分岔检测是可能的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信