Analytical Method Development and Validation of Metformin, Voglibose, Glimepiride in Bulk and Tablet Dosage Form by Gradient RP-HPLc

K. Neelima, Y. R. Prasad
{"title":"Analytical Method Development and Validation of Metformin, Voglibose, Glimepiride in Bulk and Tablet Dosage Form by Gradient RP-HPLc","authors":"K. Neelima, Y. R. Prasad","doi":"10.5530/PHM.2014.1.5","DOIUrl":null,"url":null,"abstract":"Background: A simple, sensitive, linear, precise, and accurate method by gradient reversed-phase-high performance liquid chromatography for the simultaneous estimation of metformin (MET), voglibose (VOG) and glimepiride (GLI) in bulk and in their combined tablet dosage form was developed and validated. Materials and Methods: The separation of the three drugs was based on the use of Inertsil ODS 3V (150 × 4.6 mm, i.e. 5 μm) column in a gradient mode. Mobile phase consisted of 0.02 M Phosphate buffer adjusted to pH 2.5 using dilute orthophosphoric acid (solvent A) and acetonitrile (solvent B) was set with gradient programming for 18 min and was delivered at 1 ml/min fl ow rate and effl uents are achieved with variable wavelength: Photodiode array detector at 230 nm. Results: The retention times of MET, VOG, and GLI were found to be 2.423, 8.191, and 11.708, respectively. The percentage assay of MET, VOG, and GLI was found to be 99.92%, 99.32, and 99.72%, respectively. Calibration curves were linear for MET, VOG and GLI at concentration ranges of 200-600 μg/ml, 0.08-0.24 μg/ml, and 0.8-2.4 μg/ml with the regression coeffi cient of 0.999 for all the three drugs and precise with (% relative standard deviation Conclusion: The method was validated by determining its linearity, accuracy, precision, system suitability and can be employed for routine quality control analysis as per International Conference on Harmonization guidelines. Key words: Glimepiride, gradient reversed-phase-high performance liquid chromatography, International Conference on Harmonization guidelines, metformin, validation, voglibose.","PeriodicalId":19960,"journal":{"name":"Pharmaceutical Methods","volume":"42 1","pages":"27-33"},"PeriodicalIF":0.0000,"publicationDate":"2014-07-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pharmaceutical Methods","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5530/PHM.2014.1.5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

Abstract

Background: A simple, sensitive, linear, precise, and accurate method by gradient reversed-phase-high performance liquid chromatography for the simultaneous estimation of metformin (MET), voglibose (VOG) and glimepiride (GLI) in bulk and in their combined tablet dosage form was developed and validated. Materials and Methods: The separation of the three drugs was based on the use of Inertsil ODS 3V (150 × 4.6 mm, i.e. 5 μm) column in a gradient mode. Mobile phase consisted of 0.02 M Phosphate buffer adjusted to pH 2.5 using dilute orthophosphoric acid (solvent A) and acetonitrile (solvent B) was set with gradient programming for 18 min and was delivered at 1 ml/min fl ow rate and effl uents are achieved with variable wavelength: Photodiode array detector at 230 nm. Results: The retention times of MET, VOG, and GLI were found to be 2.423, 8.191, and 11.708, respectively. The percentage assay of MET, VOG, and GLI was found to be 99.92%, 99.32, and 99.72%, respectively. Calibration curves were linear for MET, VOG and GLI at concentration ranges of 200-600 μg/ml, 0.08-0.24 μg/ml, and 0.8-2.4 μg/ml with the regression coeffi cient of 0.999 for all the three drugs and precise with (% relative standard deviation Conclusion: The method was validated by determining its linearity, accuracy, precision, system suitability and can be employed for routine quality control analysis as per International Conference on Harmonization guidelines. Key words: Glimepiride, gradient reversed-phase-high performance liquid chromatography, International Conference on Harmonization guidelines, metformin, validation, voglibose.
梯度反相高效液相色谱法建立二甲双胍、伏格列糖、格列美脲散装和片剂的分析方法及验证
背景:采用梯度反相高效液相色谱法同时测定二甲双胍(MET)、伏格糖(VOG)和格列美脲(GLI)原料药和联合片剂的含量,建立了一种简单、灵敏、线性、精确、准确的方法。材料与方法:采用Inertsil ODS 3V色谱柱(150 × 4.6 mm,即5 μm)梯度分离。流动相为0.02 M磷酸盐缓冲液,用稀正磷酸(溶剂A)和乙腈(溶剂B)调至pH 2.5,梯度编程设置18 min,以1 ml/min流速输送,采用可变波长:光电二极管阵列检测器,230 nm。结果:MET、VOG和GLI的保留次数分别为2.423、8.191和11.708。MET、VOG和GLI的百分比测定结果分别为99.92%、99.32%和99.72%。在200 ~ 600 μg/ml、0.08 ~ 0.24 μg/ml和0.8 ~ 2.4 μg/ml浓度范围内,三种药物的MET、VOG和GLI的校准曲线均为线性,回归系数为0.999,相对标准偏差为(%)。结论:通过线性、准确度、精密度和系统适用性验证了该方法的正确性,可按照国际统一会议标准进行常规质量控制分析。关键词:格列美脲,梯度反相高效液相色谱法,国际统一指南会议,二甲双胍,验证,伏格糖
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信