Hepatic veins gas bubbles in a case of emphysematous pyelonephritis

IF 0.4 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Sonography Pub Date : 2023-02-20 DOI:10.1002/sono.12347
Kai‐Wee Schrader, Jacqualine Saunders
{"title":"Hepatic veins gas bubbles in a case of emphysematous pyelonephritis","authors":"Kai‐Wee Schrader, Jacqualine Saunders","doi":"10.1002/sono.12347","DOIUrl":null,"url":null,"abstract":"measurements of a cross-section area and then reconstructing them into an image. According to a report, ultrasound has a better temporal resolution in a defined area, in comparison to CT. 16 Temporal resolution is of little importance for most applications of CT, as the structures imaged have minimal or no movement, except in cardiac CT. 17 Hence, fast moving gas bubbles in the IVC and HV, may not be demonstrated on a CT examination. In a water bath study it was demonstrated that ultrasound also has a higher sensitivity in detecting very tiny gas bubbles, in comparison to CT. 16 The experiment showed that immediately after the filling of a cup with water, ultrasound was able to demonstrate countless echogenic foci, representing gas bubbles. However, these gas bubbles only contribute to a slight decrease of density values on CT. Hence no gas bubbles were detectable on CT.","PeriodicalId":29898,"journal":{"name":"Sonography","volume":"20 1","pages":"94 - 97"},"PeriodicalIF":0.4000,"publicationDate":"2023-02-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sonography","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/sono.12347","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

measurements of a cross-section area and then reconstructing them into an image. According to a report, ultrasound has a better temporal resolution in a defined area, in comparison to CT. 16 Temporal resolution is of little importance for most applications of CT, as the structures imaged have minimal or no movement, except in cardiac CT. 17 Hence, fast moving gas bubbles in the IVC and HV, may not be demonstrated on a CT examination. In a water bath study it was demonstrated that ultrasound also has a higher sensitivity in detecting very tiny gas bubbles, in comparison to CT. 16 The experiment showed that immediately after the filling of a cup with water, ultrasound was able to demonstrate countless echogenic foci, representing gas bubbles. However, these gas bubbles only contribute to a slight decrease of density values on CT. Hence no gas bubbles were detectable on CT.
肺气肿性肾盂肾炎的肝静脉气泡
测量横截面积,然后将其重建成图像。据报道,与CT相比,超声在限定区域内具有更好的时间分辨率。时间分辨率对于大多数CT应用并不重要,因为成像的结构很少或没有运动,除了心脏CT。因此,在CT检查中可能无法显示下腔静脉和下腔静脉中快速移动的气泡。在一项水浴研究中,与CT相比,超声在检测非常微小的气泡方面也具有更高的灵敏度。16实验表明,在杯子装满水后,超声波能够立即显示无数的回声灶,代表气泡。然而,这些气泡只会导致CT上密度值的轻微下降。CT未见气泡。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Sonography
Sonography RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
0.80
自引率
0.00%
发文量
44
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信