Performance Evaluation of MRI Based on Newly Developed MRiLab Simulation Using Inversion Recovery Pulse Sequence with Various Inversion Times

IF 0.6 4区 材料科学 Q4 MATERIALS SCIENCE, MULTIDISCIPLINARY
Gaeun Baek, Jun Lim, J. Yoon, Youngjin Lee
{"title":"Performance Evaluation of MRI Based on Newly Developed MRiLab Simulation Using Inversion Recovery Pulse Sequence with Various Inversion Times","authors":"Gaeun Baek, Jun Lim, J. Yoon, Youngjin Lee","doi":"10.4283/jmag.2022.27.2.210","DOIUrl":null,"url":null,"abstract":"Among the representative types of magnetic resonance imaging (MRI) sequences, inversion recovery (IR) can improve the ability to detect brain lesions. The purpose of this study was to confirm the MRI characteristics according to TI changes in IR sequences. In this study, the MRiLab simulation program a newly developed, well-validated program was used to quantitatively analyze image characteristics with respect to the TI value in the IR sequence. Brain tissue phantom and standard phantom images were acquired by changing the TI at 100-ms intervals from 100 to 2,500 ms. In brain tissue phantom images, signal intensity (SI) values showed the lowest signals at TI values of 400, 700, and 2,500 ms in the white matter (WM), gray matter (GM), and cerebrospinal fluid (CSF), respectively. The contrast evaluated in CSF-WM was superior at 400 ms and the lowest at 1,800 ms. In addition, the contrast evaluated in WM-GM was superior at 400 ms and the lowest at 1,500 ms. In the case of the brain standard phantom, the SI and contrast showed the same tendency as brain tissue phantom. In conclusion, an appropriate TI value was derived for obtaining images with excellent SI and contrast between brain tissues using a newly developed simulation program.","PeriodicalId":16147,"journal":{"name":"Journal of Magnetics","volume":"52 1","pages":""},"PeriodicalIF":0.6000,"publicationDate":"2022-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Magnetics","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.4283/jmag.2022.27.2.210","RegionNum":4,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Among the representative types of magnetic resonance imaging (MRI) sequences, inversion recovery (IR) can improve the ability to detect brain lesions. The purpose of this study was to confirm the MRI characteristics according to TI changes in IR sequences. In this study, the MRiLab simulation program a newly developed, well-validated program was used to quantitatively analyze image characteristics with respect to the TI value in the IR sequence. Brain tissue phantom and standard phantom images were acquired by changing the TI at 100-ms intervals from 100 to 2,500 ms. In brain tissue phantom images, signal intensity (SI) values showed the lowest signals at TI values of 400, 700, and 2,500 ms in the white matter (WM), gray matter (GM), and cerebrospinal fluid (CSF), respectively. The contrast evaluated in CSF-WM was superior at 400 ms and the lowest at 1,800 ms. In addition, the contrast evaluated in WM-GM was superior at 400 ms and the lowest at 1,500 ms. In the case of the brain standard phantom, the SI and contrast showed the same tendency as brain tissue phantom. In conclusion, an appropriate TI value was derived for obtaining images with excellent SI and contrast between brain tissues using a newly developed simulation program.
基于不同反转时间的反转恢复脉冲序列MRiLab仿真的MRI性能评价
在磁共振成像(MRI)序列的代表性类型中,反转恢复(IR)可以提高对脑部病变的检测能力。本研究的目的是根据IR序列的TI变化来确定MRI特征。在本研究中,MRiLab模拟程序是一个新开发的,经过良好验证的程序,用于定量分析红外序列中TI值的图像特征。脑组织幻像和标准幻像是通过在100到2500 ms之间每隔100 ms改变一次TI来获得的。在脑组织幻像中,信号强度(SI)值分别在TI值为400ms、700ms和2500ms时,白质(WM)、灰质(GM)和脑脊液(CSF)信号强度最低。CSF-WM评价的对比度在400 ms时最高,在1800 ms时最低。此外,在400 ms时,WM-GM评估的对比度最好,在1500 ms时最低。在脑标准幻像的情况下,SI和对比显示与脑组织幻像相同的趋势。总之,使用新开发的模拟程序,可以获得具有良好SI和脑组织对比度的图像,从而获得适当的TI值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Magnetics
Journal of Magnetics MATERIALS SCIENCE, MULTIDISCIPLINARY-PHYSICS, APPLIED
CiteScore
1.00
自引率
20.00%
发文量
44
审稿时长
2.3 months
期刊介绍: The JOURNAL OF MAGNETICS provides a forum for the discussion of original papers covering the magnetic theory, magnetic materials and their properties, magnetic recording materials and technology, spin electronics, and measurements and applications. The journal covers research papers, review letters, and notes.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信