{"title":"Comparison of Seismic Behaviour of Multi Storey Reinforced concrete Structure with Dual System","authors":"A. Ahmed, A. Abdulla, A. Ahmed","doi":"10.32622/ijrat.79201909","DOIUrl":null,"url":null,"abstract":"1 doi: 10.32622/ijrat.79201909 Abstract— In general, the structure can be prone to serious harm in elevated seismic regions. Along with the structure of the gravity load, the lateral load must be able to create elevated stresses. Now a days the shear wall in R.C structure with the steel structure and steel bracing system is most common for resisting lateral loads due to earthquake, wind, blast, etc. One of the finest lateral load resisting system is the shear wall. which is widely used in construction world. This study includes linear-static and non-linear static analysis of an E-shaped and diaphragm discontinuity G+ 14 multi-story RC building with different shear wall arrangements on dual system such as flat slab and shear wall, moment-resistant frames and shear wall using ETABS software for various irregular designs. Parameters like base shear, storey shear, storey drift, displacement.","PeriodicalId":14303,"journal":{"name":"International Journal of Research in Advent Technology","volume":"52 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Research in Advent Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32622/ijrat.79201909","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
1 doi: 10.32622/ijrat.79201909 Abstract— In general, the structure can be prone to serious harm in elevated seismic regions. Along with the structure of the gravity load, the lateral load must be able to create elevated stresses. Now a days the shear wall in R.C structure with the steel structure and steel bracing system is most common for resisting lateral loads due to earthquake, wind, blast, etc. One of the finest lateral load resisting system is the shear wall. which is widely used in construction world. This study includes linear-static and non-linear static analysis of an E-shaped and diaphragm discontinuity G+ 14 multi-story RC building with different shear wall arrangements on dual system such as flat slab and shear wall, moment-resistant frames and shear wall using ETABS software for various irregular designs. Parameters like base shear, storey shear, storey drift, displacement.