{"title":"Tertiary Containment in a Multi-Room Tritium Facility","authors":"L. Kent","doi":"10.13182/FST85-A24656","DOIUrl":null,"url":null,"abstract":"An experimental system to provide tertiary containment at Mound has been upgraded to support a new multi-room tritium handling facility. This system is used to remove tritium from room air in the event of primary (process) and secondary (glovebox) containment failure. The upgraded system includes a faster response time, piping and valves that are more leaktight, and a new control panel that better indicates the system status and operating conditions.","PeriodicalId":22517,"journal":{"name":"The International journal of applied radiation and isotopes","volume":"30 1","pages":"2511-2516"},"PeriodicalIF":0.0000,"publicationDate":"1985-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of applied radiation and isotopes","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.13182/FST85-A24656","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
An experimental system to provide tertiary containment at Mound has been upgraded to support a new multi-room tritium handling facility. This system is used to remove tritium from room air in the event of primary (process) and secondary (glovebox) containment failure. The upgraded system includes a faster response time, piping and valves that are more leaktight, and a new control panel that better indicates the system status and operating conditions.