Nobuyuki Yoshida, Scott J. McNiven, Akira Yoshida, Takashi Morita, Hideaki Nakamura, Isao Karube
{"title":"A compact optical system for multi-determination of biochemical oxygen demand using disposable strips","authors":"Nobuyuki Yoshida, Scott J. McNiven, Akira Yoshida, Takashi Morita, Hideaki Nakamura, Isao Karube","doi":"10.1002/fact.10001","DOIUrl":null,"url":null,"abstract":"<p>A compact optical device and disposable strips for the simultaneous determination of the biochemical oxygen demand (BOD) of multiple samples have been developed. The compact optical device was constructed using three pairs of light emitting diodes (LEDs) and silicon photodiodes (Si-PDs), and the disposable strips were fabricated using inexpensive, transparent polycarbonate plates. <i>Pseudomonas fluorescens</i> bacteria were immobilizedin a layer at the bottom of each reaction cell on the sensor strip using a photocrosslinkable resin (ENT-2000). Using the redox electron acceptor 2,6-dichlorophenolindophenol sodium salt as the chromophore, a linear relationship was observed between the response of the Si-PDs and the BOD value of Organization of Economic Cooperation synthetic wastewater. Real samples from a wastewater treatment plant and a kitchen in our factory were examined, and good correlations were observed between the BOD values derived using this system and those determined by the conventional BOD<sub>5</sub> method. In addition, in spite of the sensor response decreasing to approximately half its initial value after 2 weeks, the correlation coefficients (<i>r</i><sup>2</sup>) of calibration curves remained above 0.9 upon storage of the strips in 0.1 M NaCl solution at 4°C for up to 6 weeks. In conclusion, this system is transportable and compact as well as being simple to operate and suitable for rapid, on-site measurements. © 2001 John Wiley & Sons, Inc. Field Analyt Chem Technol 5: 222–227, 2001</p>","PeriodicalId":100527,"journal":{"name":"Field Analytical Chemistry & Technology","volume":"5 5","pages":"222-227"},"PeriodicalIF":0.0000,"publicationDate":"2001-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/fact.10001","citationCount":"19","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Field Analytical Chemistry & Technology","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/fact.10001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 19
Abstract
A compact optical device and disposable strips for the simultaneous determination of the biochemical oxygen demand (BOD) of multiple samples have been developed. The compact optical device was constructed using three pairs of light emitting diodes (LEDs) and silicon photodiodes (Si-PDs), and the disposable strips were fabricated using inexpensive, transparent polycarbonate plates. Pseudomonas fluorescens bacteria were immobilizedin a layer at the bottom of each reaction cell on the sensor strip using a photocrosslinkable resin (ENT-2000). Using the redox electron acceptor 2,6-dichlorophenolindophenol sodium salt as the chromophore, a linear relationship was observed between the response of the Si-PDs and the BOD value of Organization of Economic Cooperation synthetic wastewater. Real samples from a wastewater treatment plant and a kitchen in our factory were examined, and good correlations were observed between the BOD values derived using this system and those determined by the conventional BOD5 method. In addition, in spite of the sensor response decreasing to approximately half its initial value after 2 weeks, the correlation coefficients (r2) of calibration curves remained above 0.9 upon storage of the strips in 0.1 M NaCl solution at 4°C for up to 6 weeks. In conclusion, this system is transportable and compact as well as being simple to operate and suitable for rapid, on-site measurements. © 2001 John Wiley & Sons, Inc. Field Analyt Chem Technol 5: 222–227, 2001
用于一次性试纸多次测定生化需氧量的紧凑光学系统
研制了一种可同时测定多种样品生化需氧量(BOD)的小型光学装置和一次性试纸条。紧凑的光学器件由三对发光二极管(led)和硅光电二极管(si - pd)组成,一次性光条由廉价、透明的聚碳酸酯板制成。使用光交联树脂(ENT-2000)将荧光假单胞菌固定在传感器条上每个反应细胞底部的一层中。以氧化还原电子受体2,6-二氯酚吲哚酚钠盐为发色团,观察了si - pd的响应与经合组织合成废水的BOD值之间的线性关系。对我们工厂污水处理厂和厨房的实际样品进行了检测,观察到使用该系统得出的BOD值与传统BOD5法测定的BOD值之间存在良好的相关性。此外,尽管传感器响应在2周后下降到初始值的一半左右,但在4°C的0.1 M NaCl溶液中保存6周后,校准曲线的相关系数(r2)仍保持在0.9以上。总之,该系统可运输,紧凑,操作简单,适用于快速,现场测量。©2001 John Wiley &儿子,Inc。化学工程学报,2009,31 (2):444 - 444
本文章由计算机程序翻译,如有差异,请以英文原文为准。